Armstrong Air NP14A Series Panduan Petunjuk Pemasangan dan Pemeliharaan - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pemasangan dan Pemeliharaan untuk Pendingin Udara Armstrong Air NP14A Series. Armstrong Air NP14A Series 20 halaman. Residential packaged units

Armstrong Air NP14A Series Panduan Petunjuk Pemasangan dan Pemeliharaan
Roof Curb Dimensions - Small Base Air Conditioners & Heat Pumps
Opening for Power Entry
Through Unit Base
5-1/2 x 5-5/8 in.
(140 x 31 mm)
Insulated
Panels
Opening for Power Entry
Through Unit Base
3 x 13 in.
(76 x 330 mm)
Page 4 of 20
44-3/8
(1127)
44-3/8
(1127)
NOTE - Roof deck may be omitted within confines of curb.
3/4 (19)
11-1/2
(287)
3
(76)
1-3/8
13
(35)
(330)
3-3/4
(95)
Issue 2211
RETURN
OPENING
16-7/8
(429)
2-1/8
(54)
5-3/4
(146)
SUPPLY
5-1/2
OPENING
(140)
17-1/4
(438)
13-7/8
(352)
8 (203)
14 (356)
18 (457)
11-1/2
24 (610)
(287)
507296G03 / 31-5000670