DISCOVER 15-24-1000 Panduan Pengoperasian - Halaman 7
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Aksesori Kamera DISCOVER 15-24-1000. DISCOVER 15-24-1000 11 halaman. Lithium ion battery
Systems should be put into storage at 80% SOC and checked monthly to ensure the system SOC does not fall below 20%. At 20%
SOC the battery will self discharge in approximately 2 months.
7. Protection & Faults
• BMS generates faults when maximum operating limits are reached.
• BMS sounds a buzzer when fault limits are triggered.
• BMS monitors the following information for faults and warning:
1. Cell module voltage
2. Battery current
3. Battery temperature
7.1 Faults
In the event of a fault the BMS will sound an audible buzzer warning and the system will shut off after a 120 second delay.
When the operating conditions are within acceptable ranges, the battery can be recovered from Fault by pushing the ON-OFF
button.
Minimum Storage Temperature
Maximum Storage Temperature
FLASHING LED
Parameter
High Temperature in Discharge
High Temperature in Charge
High Voltage
Low Temperature in Discharge
Low Temperature in Charge
Low Voltage
Over Current
In-rush Current
CORRECTIVE ACTIONS
High Temperature
Low Temperature
High Voltage
Low Voltage
Over Current
Low SOC
-20°C / -4°F
45°C / 113°F
Low State of Charge
Charge
Over Voltage
Stop charge
Over Current
Reduce current
FAULT LEVELS
Trigger Point
60°C / 140°F for 2s
45°C / 113°F for 2s
3.7 V in any cell module 2s
-20°C / -4°F for 2s
-1°C / 30°F for 2s
2.8 V in any cell module for 2s
> 45 A for 5 sec.
200 to 260 A for 640ms
• Stop discharge or charge
• Leave the battery to cool
• Stop discharge or charge
• If charging stop the charge
• Do not discharge the battery. Any
discharge current detected will force
the battery into Low Voltage Fault
• The user can charge the battery in
Low Voltage Recovery
• If no charge current is detected
within 2 minutes the BMS will turn
off the battery
• Reduce current
• Stop discharge
• Charge the battery
Over Temperature
Stop using/let cool
Short Circuit
Check external
circuits
7