ARO PD10E Series Panduan Operator - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Operator untuk Pompa Air ARO PD10E Series. ARO PD10E Series 8 halaman. 1” diaphragm pump

ARO PD10E Series Panduan Operator
107
105
133
135
134
43
111
137
136
107
236
PD10E-X-X (en)
PARTS LIST / PD10E-X-X AIR SECTION
173
118
169
174
121
167
140
141
233
Notch
200
Insert screwdriver here to remove (233) adapter plate.
138
139
MAJOR
VALVE
A 637395-7 replacement Major Valve Service Assembly is available separately, which includes the following:
105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166, 176 (2), 200, 233, and 236 (4)
168
172
171
170
166
132
176
101
Figure 3
TORQUE REQUIREMENTS
NOTE: DO NOT OVERTIGHTEN FASTENERS.
ALL FASTENERS ARE METRIC.
Torque (105 and 134) screw to 35 - 40 in. lbs (4.0 - 4.5 Nm).
LUBRICATION / SEALANTS
Apply Lubriplate FML-2 grease to "O" rings, "U" Cups & mating parts.
Apply anti-seize compound to threads at assembly.
PILOT VALVE
PART GROUP
181
103
201
173
118
121
174
Page 7 of 8