Aroma360 Davinci360 Panduan Pengguna - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Aksesori Aroma360 Davinci360. Aroma360 Davinci360 2 halaman.
Juga untuk Aroma360 Davinci360: Panduan Pemecahan Masalah (2 halaman)

Aroma360 Davinci360 Panduan Pengguna
At a Glance
POWER
The bottom silver button on the side of the unit is used to turn the
DaVinci360 on and o . Press once for on and once for o .
FAN
The switch on the top of the di user controls the fan. Turning on the fan
will increase the coverage area. The circle pressed in indicates the fan is
o , the dash pressed in means the fan is on.
LOCK SETTINGS
The lock setting will prevent any tampering with the unit's programming.
To lock the settings, hold down the SET button for 20 seconds. A short
beep will confirm the settings have been locked. You will need to unlock
the unit to adjust the settings. To do so, hold the SET button again for 20
seconds and the short beep will indicate the settings have been unlocked.
FACTORY RESET
If you want to reset the unit to factory settings, hold down the MODE
button for 20 seconds and the unit will return to the following settings:
8am – 10pm at 60% for seven days/week.
What's included:
• The DaVinci360 Di user Unit
• 200 mL Aluminum Bottle
• 12V Adapter Cord
• Wall Mounting Brackets
• Spare Nozzle (Black Cone Shaped Piece)
• Two Keys
Understanding Your DaVinci360
The DaVinci360's LCD display provides valuable information about your
settings. Here is a quick guide on what each item means.
WORK/PAUSE —When the unit is in WORK mode, it is emitting scent. When
the unit is in PAUSE mode, it is not emitting scent.
TIME — The number displayed on the unit should represent the current time,
using the 24-hour clock.
DAY OF THE WEEK — The DaVinci360 allows you to have di erent settings for
di erent days. The day that's shown on the display should be the current day.
SCENT/WORK/PAUSE — This screen appears when adjusting the scent
intensity level and the number represents a percentage. 5 is the lowest setting
which means the scent intensity is 5% and 95 is the highest which means the
scent intensity is 95%.
Setting Up Your DaVinci360
1
Unbox your new DaVinci360 and familiarize yourself with the parts and
accessories.
2
Insert the adapter into the DaVinci360's power source and plug the adapter
into the outlet. Press in the power button located on the side of the di user
2
to turn it on.
Now that the di user is powered on, you may begin adjusting the settings to
1
your liking. By default, the LCD screen will depict the current time. Note the
unit uses a 24-hour clock so 5:30p.m. will be shown as 17:30
Setting the Current Time
1
To set the current time, press SET, and the hour will flash. Press UP or
DOWN to adjust to the current hour and press set to confirm your choice.
(If your screen is unresponsive, press and hold the SET button for 20
seconds).
2
The minute will now be flashing. Press UP or DOWN to adjust to the
current minute and press SET to confirm your choice.
3
The day of the week will now be flashing. Press UP or DOWN to adjust to
the current day of the week and press SET to confirm
W W W. AROMA 360.COM
5 6 1 . 2 0 6 . 0 0 5 3
Setting the Operating Hours and Scent Intensity
Now it's time to set your event "operating" periods. The DaVinci360
allows up to five individual event operating periods so you can scent at
various times on di erent days of the week. For each operating period
you will need to set the "ON" time, days of the week "OFF" time and
scent intensity level
1
To set start time of a scenting period: Press MODE. EVENT 1 ON will
appear. This represents the On time for the first operating period. Press
SET and the hour will flash. Use the arrows to adjust the hour up or
down. Once satisfied with your selection, press SET and the minutes will
flash. Adjust as needed, press SET and the days of the week will flash.
Use the arrows to select the days you'd like to apply the settings to.
2
Once satisfied with the EVENT 1 ON info, you can set the end time of the
scenting period: Press MODE. EVENT 1 OFF will appear. This represents
the O Time for the first operating period. Set time as instructed above.
3
Press MODE and "SCENT, WORK, PAUSE" will appear on the screen.
This is the scent intensity level represented as a percent. Press the up or
down arrows to adjust the scent level. 5 is the lowest setting and 95 is
the highest.
4
Once you have the desired scent intensity, press MODE and EVENT 2
ON will appear. This will allow you to set the On Time and scent intensity
for the second and remaining working periods if you plan on using
3
multiple day/time settings If you only have one working period, then
press MODE until you reach the end of the event settings to confirm your
current settings.
Setup Tips
Ensure there are no conflicting settings.
The unit cannot be set to run past midnight. You must split the setting
between two di erent operating periods. For example, if you want the
unit to run from 10pm – 4am, it would be set as follows:
i. EVENT 1 ON — 22:00 EVENT 1 OFF — 23:59
ii. EVENT 2 ON — 00:01 EVENT 2 OFF — 04:00
Technical Specifications
UNIT DIMENSION
VOLTAGE
POWER
NOISE LEVEL
UNIT WEIGHT
COVERAGE
COLOR
DISPERSION
7 ¼ x 3 ½ x 9 (inches)
18.4 x 8.89 x 22.86 (cm)
DC12V
8 watts or 0.67 amps
<56dba
9 lbs.
(4.08 kgs)
800 sq. ft.
(74.3 m2)
Black or white
HVAC or Stand-Alone