Warning and lighting devices
Gate open warning-light
- For warning that the gate is open. It stops fl ashing when the gate closes.
Movement warning fl ashing-light
- Itfl ashes when the gate is opening and closing.
E_W
CONTACTS
rated for
230V - 25W max.
E_E3
230V - 60W max.
Courtesy light.
10_5
24V - 3W max.
- It stays on for a fi xed time of 5 minutes
from the moment in which the gate-
leaves start their maneuver.
10 11 S
1
2
3 3P 4
5
7
2
U
V
W
X
Y
E E3
Command and control devices
Stop button (N.C. contact).
- For commandingthe gate to stop while excluding the automatic-closing time
cycle. To resume movement, press a button on the control or the transmitter
11 S
1
2
3 3
button.If unused, short-circuit terminals 1-2.
Key-switch selector and/or opening button (N.O. contact).
- For commanding the gate to open.
Key-switch selector and/or partial opening button (N.O. contact).
- For commanding the partial opening of a leaf (M2). ) for pedestrian passage.
Key-switch selector and/or closing button (N.O. contact).
- For commanding the gate to stop.
Key-switch selector and/or command button (N.O. contact).
- Forcommanding the opening and closing of the gate. By pressing the button
or turning the selector key, the gate inverts its movement or stops, depending
on the selection made on the DIP-switches (see selecting functions, DIP-
switches 2 and 3).
10 11 S
1
2
3 3P 4
5
7