Alto TW 300 S Panduan Petunjuk Pengoperasian - Halaman 10

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Mesin Lantai Alto TW 300 S. Alto TW 300 S 12 halaman. Spray extraction cleaner
Juga untuk Alto TW 300 S: Lampiran Petunjuk Pengoperasian (18 halaman), Panduan Petunjuk Pengoperasian (12 halaman)

Alto TW 300 S Panduan Petunjuk Pengoperasian

TROUBLESHOOTING

Fault
Motor does not run
‡ Weak spraying force
‡ Weak suction force
10
Cause
> Power supply
interrupted
> Spray nozzle clogged
> Filter in fresh water
tank clogged
> Fresh water tank
empty
> Pressure pump
defective
> Lid not fitted correctly
on dirty water tank (air
leaks)
> Nozzle clogged
> Suction hose
connections not
correctly fitted (air
leaks)
> Dirty water tank is full.
Float stops suction
flow
> Air filter clogged
> TW 1400 HD only:
Dirty water drain hose
not closed
Remedy
Check mains lead,
plug socket, fuse
Clean and/or descale
nozzle
Clean
Refill. Beforehand,
empty dirty water tank
• Call Alto technician or
authorised specialist
Fit lid tightly; check
gasket
Clean
Check
Empty dirty water tank
Clean
Close