Camina Art Supreme Instruksi dan Penggunaan Perakitan - Halaman 6

Jelajahi secara online atau unduh pdf Instruksi dan Penggunaan Perakitan untuk Kompor kayu Camina Art Supreme. Camina Art Supreme 12 halaman.

Camina Art Supreme Instruksi dan Penggunaan Perakitan
Assembly
Cutting a hole in a
masonry chimney
Chimney insert
Design
requirements
The stove and the chim-
ney must be arranged in a
way that ensures that they
cannot start a fire in adjoi-
ning fixtures or parts of
the building. The flue must
be installed in a manner
which permits chimney-
sweeping for the full flue
length, and with ready
access to cleaning doors.
6
Connection to an existing masonry chimney
The stove is approved for a rear connection to a chimney with a ½ brick con-
nection point which is approved for a 350
1. Measure where the hole is to be made in the chimney. Mark the hole and chisel it out
so that it is slightly larger than the diameter of the chimney insert, allowing sufficient space
to cement the insert in place, using mortar. Cement the insert into the hole.
The stove is normally supplied
for a top connection. If you
intend to employ a rear con-
nection, use the rear-connection
cover plate instead to replace
the insert on top of the stove.
Apply stove sealant to ensure
a good seal between the stove
and the cover plate.
When connecting the stove to a proprietary modular chimney, follow the manufacturer's
instructions.
1.
Place the floor plate/fireplace base in position.
2.
If you are going to connect the stove from the top into the masonry chimney,
the loose top stone unit should be placed in position before the flue pipe is
fitted.
3.
Apply stove sealant to the stove insert and push the flue pipe into position. The stove is
then placed in position and the flue pipe is cemented in place. If you are using a chimney
insert, tamp in packing fibre around the flue pipe. Check that the distances are correct.

Design specifications

Colour
Glass, ceramic
Door
Grate
Hearth base
Hearth lining
The hearth is approved for a chimney with a ½ brick connection (350
the stove is designed for a chimney draught of at least 12 pa, as provided by a
chimney with a minimum length of 3.5 metres and a cross-section of 150-200
cm
(diam. 150 mm).
2
Output
Nominal output
Efficiency (SS-EN 13240)
Weights:
Camina Art Suprême
Camina Art Grace
Camina Art Étage
Camina Art Moderne
Camina Art Pierre
Flue-pipe diameter
Product-type and environmental approval
CE-approval

Optional extras

Outdoor air connection
Fan
Soapstone base (only for Grace/Etage)
Cast iron base (only for Grace/Etage)
Floor protection, straight or curved
Floor protection, straight or curved
C flue-gas temperature.
0
Fit the connection pipe which
is to be fitted into the chimney
insert over the stove connection
insert. Apply a thin layer of
stove sealant around the insert
before fitting the connection
pipe.
Senotherm
Withstands 700
Sheet steel
Cast iron
Cast iron
Vermiculite
Diam. 60 mm
240 V
15 kg
Toughened glass
Grey sheet metal
As an alternative to a straight
rear connection, you can use
a top/rear connection to a
masonry chimney. In this case,
the angle must have an inspec-
tion door to permit cleaning.
C
0
C), and
0
2-8 kW
5.5 kW
70%
122 kg
124 kg
124 kg
210 kg
190 kg
150 mm
39 53 03
0402