Data interface Modbus TCP and ESERA ASCII text protocol
The Ethernet interface is configured using the Windows ESERA program "Config-Tool 3".
You can find this program in the download area of the ESERA online shop.
11
Integration in IP-Symcon / ESERA-Station
ESERA IP-Symcon software modules are provided at our webpage for easy integration of the 4-fold analog
input in IP-Symcon by using a 1-Wire Controller / 1-Wire Gateway. Using software scripts are no longer
necessary. Further details can be found on our webpage:
zentralen/ip-symcon-integration/.
A script for regular connections by 1-Wire Bus Coupler is also available for download on our webpage.
Further details can be found in the sample script.
12
Integration in Loxone
We provide a sample project e.g. for read out analog voltages by 4-fold analog input via
1-Wire Controller 1 in our webshop.
Further details can be found here:
integration/demo-1-wire-controller-1-loxone-integration/
13
Integration in FHEM
We provide a software module for easy integration in the Open Source automation software FHEM of the
4-fold analog input into FHEM by 1-Wire Controller / 1-Wire Gateway. Using this software scripts are no
longer necessary. Further details can be found on our webpage:
steuerungen-zentralen/fhem-integration/
14
Configuration and communication with 1-Wire Gateway 20
1-Wire Gateway 20 offers various configuration and formatting options. All options can be read out and
controlled by the ESERA Config-Tool 3. 1-Wire Gateway and Config-Tool 3 communication is based on
an open ESERA ASCII text protocol. Therefore configuration and data transfer with any terminal program
(such as Hercules or Putty) by UDP/TCPIP and 1-Wire Gateway 20 is possible at any time. For detailed
communication commands please refer to the
our webshop.
15
Firmware-Update
Firmware will be updated by using a Config-Tool
3 software which can be found at the
"DEBUG/DATA" tab. By clicking the button
"DOWNLOAD FIRMWARE" a new window
opens to download new software (firmware) for
the 1-Wire Controller / 1-Wire Gateway.
This firmware is compatible with all releases of
the 1-Wire Controller and 1-Wire Gateways. The
features are individually unlocked at the installed
device. Starting with firmware version V1.18_38
the reset button of the 1-Wire Controller / 1-Wire
Gateway does not need to be pressed for
updates anymore.
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de
https://www.esera.de/kompatible-steuerungen-zentralen/loxone-
"Programming
11337 V2.0 R1.0 Manual
https://www.esera.de/kompatible-steuerungen-
https://www.esera.de/kompatible-
Manual" which is available for download in
Page 7 of 10