Eseye Intelligent Cloud Connect Panduan Memulai Cepat - Halaman 2

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Terminal sentuh Eseye Intelligent Cloud Connect. Eseye Intelligent Cloud Connect 4 halaman.

Establishing a cellular connection
Ensure you have connected the terminal antenna to the Antenna
connection.
To power on and establish your cellular connection:
1. Fully insert the SIM card into the Intelligent Cloud Connect.
You can see how to insert the SIM on the underside of
the terminal. The socket is a push-to-insert, push-to-
release type socket. When the SIM is properly
inserted, it clicks into place and sits flush with the
edge of the SIM slot.
2. Turn on the Intelligent Cloud Connect.
The Intelligent Cloud Connect connects to a cellular network
using the Cinterion® PLS62-W Wireless Module, and is now
ready to receive security and identity information from AWS.
Provisioning the Cinterion® PLS62-W Wireless
Module
Eseye automatically provisions the AnyNet Secure SIM. During this
process, the security and identity information is downloaded and
programmed into the SIM card. You can observe the provisioning
progress in the device shadow. You can access the shadow using
Lambda functions, programatically, or through the AWS IoT Console .
1. Using the AWS IoT Console , select the thing you created with the
matching SIM number.
2. On the Device Shadows tab, select Classic Shadow to view the
Device Shadow document .
Use the Device Shadow state pane to view the certificate
delivery progress. The certificate is delivered after the status
changes from Pending to Provisioned. You can also view smart
terminal message consumption and location information.
8582 Intelligent Cloud Connect Quick Start Guide v1.10
©2021 Eseye Ltd. All rights reserved.
Provisioning normally takes 5-10 minutes to complete,
although the process may take up to an hour. If your
Cinterion® PLS62-W Wireless Module has not connected
in 24 hours, contact Support: [email protected].
During provisioning, the Cinterion® PLS62-W Wireless Module will
reset four times. Use a terminal emulator to observe this process.
For information about setting up a terminal emulator, see
Attaching to the Intelligent Cloud
When the device is ready, it sends the following URC:
+EMT:EMQRDY
You must wait until you receive the +EMT:EMQRDY
URC before you can use the device to send and
receive commands.
If you are using the Intelligent Cloud Connect, and the
device is not connecting, check the LEDs:
• A green LED indicates power on.
• A flashing orange LED indicates network registration
status. Regular half second blinking indicates that the
Cinterion® PLS62-W Wireless Module is searching
for a network. A brief flash every four seconds
indicates that the device has registered to a network
and there is no data transfer.
For more information about the LEDs, refer to the Thales
AT Command documentation.
Sending data from your thing to the cloud
Before you begin
• Using a terminal emulator, send an AT<return> command to
ensure that the smart terminal can receive AT commands.
For information about connecting a terminal
emulator to the modem, see
Intelligent Cloud
• Send an AT+ETMINFO=version<return> command to
verify that the version number is 2.0.20 or higher.
• Ensure you know the thing name that you set up in AWS.
To test that your thing can publish information to AWS:
1. Create two publish topics in the Cinterion® PLS62-W Wireless
Module.
a. Using a terminal emulator, type:
at+emqpubopen=0,"PublishToCloud0"<return>
at+emqpubopen=1,"PublishToCloud1"<return>
b. Check that the first two index numbers are assigned a topic
each. Type:
at+emqpubopen?<return>
2
8582 Intelligent Cloud Connect Quick Start Guide
Connect.
Attaching to the
Connect.