- 3. Lockout Feature
Partial Lockout 3
This mode allows the installer to set the Maximum
temperature Setpoint (factory default 21°c), and locks
all keys/slider except, to change the time and date, off
(frost protection) and allow temporary manual override
(temperature Up/Down arrows).
Partial Lockout 4
This mode allows the installer to set the Maximum
temperature Setpoint (factory default 21°c), and locks
all keys/slider except from off (frost protection) and
allow temporary manual override (temperature Up/
Down arrows).
Full Lockout 5
This mode locks all keys/slider. The End user cannot
adjust anything.
4. To exit the Installer Menu, press the
Permanent
Time /
Number
Program
Manual
Date
Override
1
✓
✓
2
✓
✓
3
✓
✗
4
✗
✗
5
✗
✗
N.B. *Temperature can be adjusted up to the installer
set limits.
Home button.
Temp
Manual
All Day
Holiday
Override
✓
✓
✓
✓*
✓*
✓*
✗
✓*
✗
✗
✓*
✗
✗
✗
✗
WARNING: Interference with sealed parts renders the
guarantee void.