dIXEL XB570L Panduan Pengoperasian dan Instruksi - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Instruksi untuk Pendingin dIXEL XB570L. dIXEL XB570L 6 halaman. Blast chiller
dIXEL
Mess.
Cause
"FF"
Fast freezing
interrupted by short
power failure
"PFA"
Fast freezing
interrupted by long
power failure
"OCF"
Max duration of the
cycle is expired
"EA"
External alarm
Serious external
"CA"
alarm
"dA"
Door open alarm
22. Technical data
Housing: self extinguishing ABS.
Case: frontal 185x38 mm; depth 70mm;
Mounting: panel mounting in a 150x31mm panel cut-out
Frontal protection: IP65
Connections: Screw terminal block ≤ 2,5mm
Power supply: 230Vac, ±10%
Power absorption: 5VA max.
Display: 3 digits, red LED, 14,2 mm high.
Inputs: 3 PTC or NTC probes
Relay outputs:
compressor: relay SPST 20(8)A or 8(3) A, 250Vac
defrost:: relay 8(3)A, 250Vac
fans: relay SPST 8(3)A, 250Vac
IV relay: relay SPDT 8(3)A, 250Vac
Serial output: RS232 serial output for XB05PR printer connection
Data storing: on the non-volatile memory (EEPROM).
Operating temperature: 0÷60 °C.
Storage temperature: -30÷85 °C.
Relative humidity: 20÷85% (no condensing)
Measuring range: -55÷50 °C
Resolution: 0,1 °C or 1 °F (selectable).
Accuracy of the controller at 25°C: ±0,3 °C ±1 digit
23. Standard Value of the cycles.
Cy1: for fast chilling and conservation of foods at positive temperature
dbC = no
iS2 = 5°C (41°F)
iS1 = 20°C (68°F)
rS2 =-2°C (28°F)
rS1= -10°C (14°F)
Pd2 = 2.0 h
Pd1 = 2.0 h
iS3 = 3°C (37°F)
Cy2: for chilling and fast freezing of foods with holding
dbC = no
iS2 = 5°C (41°F)
iS1 = 10°C (50°F)
rS2= -2°C (28°F)
rS1 = -10°C (14°F)
Pd2 = 2.0 h
Pd1 = 2.0 h
iS3=-18°C (0°F)
Cy3: direct fast freezing with holding
dbC = no
iS2=-18°C (0°F)
iS1 = -18°C (0°F)
rS2=-30°C(-22°F)
rS1=-30°C (-22°F)
Pd2 =OFF
Pd1 = 4.0
iS3 =-18°C (0°F)
Cy4: direct fast freezing without holding
dbC = no
iS2=-18°C (0°F)
iS1 =-18°C (0°F)
rS2=-30°C (-22°F)
rS1=-30°C (-22°F)
Pd2 =OFF
Pd1 = 4.0
iS3=-18°C (0°F)
24. Standard Values of the parameters.
Lab Description
differential
Hy
AC Anti-short cycle delay
1c2 Second compressor configuration
rPO Thermostat probe calibration
EPP Evaporator probe presence
EPO Evaporator probe calibration
1592006100 XB570L GB r1.0 04.11.2004.doc
Operating and Instructions Manual
Outputs
Alarm output ON; The freezing cycle restart
from the same point at which was interrupted.
Alarm output ON; The freezing cycle restart
from the current phase.
Alarm output ON; Other outputs unchanged.
In any case the cycle ends when the final
temperature is reached
Alarm output ON; Other outputs unchanged.
Alarm output ON; Other outputs OFF.
Alarm output ON; Other outputs unchanged.
2
wiring.
rS3=-2°C (28°F)
Pd3 = OFF
dbH = yes
HdS = 3°C (37°F)
rS3=-30°C (-22°F)
Pd3 = 2.0 h
dbH = YES
HdS =-18°C (0°F)
rS3=-30°C (-22°F)
Pd3 = OFF
dbH = yes
HdS = -18°C (0°F)
rS3=-30°C (-22°F)
Pd3 = OFF
dbH = no
HdS = OFF
Regulation
iPP Insert probe presence
iPO Insert probe calibration
Temperature measurement unit
CF
rES Resolution (for °C):
PAU Time of stand by
PFt Maximum acceptable duration of power failure
iPd Temperature difference for the automatic recognition of the insert probe
Time delay for the automatic recognition of the insert probe
iPt
Con Compressor ON time with faulty probe
COF Compressor OFF time with faulty probe
diC Digital input operating mode
diP Digital input polarity
did Digital input delay
OAC AUX output configuration
OAP AUX output polarity
OAt AUX output timer
OAS Set point for AUX output
OAH Differential for AUX output
OAi Probe selection for the AUX output
tdF Defrost type
dPO Defrost before holding cycle
IdF Interval between defrost cycles
dtE Defrost termination temperature
MdF Maximum length for defrost
dFd Temperature displayed during defrost
Fdt Drip time
FnC Fan operating mode
FSt Fan stop temperature
AFH Differential for the stop temperature and for the alarm
Fnd Fan delay after defrost
ALU MAXIMUM temperature alarm
ALL Minimum temperature alarm
ALd Temperature alarm delay
EdA Alarm delay after defrost
tbA Silencing alarm relay
Ad1 Address 1 for RS485:
Ad2 Address 2 for RS485
Lod Local display
rEd Remote display
LOC Keypad LOCK
PAS Security code set up
tPb Type of probe (readable only)
rEL Release code (readable only)
Ptb Parameter code (readable only)
Dixell S.p.A.
Z.I. Via dell'Industria, 27
32010 Pieve d'Alpago (BL) ITALY
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 989 313
E-mail: [email protected] - http://www.dixell.com
XB570L
°C/°F
2/4
1
0
0
yes
0
XB570L
1592006100
Defrost
Fans
Alarm
Others
yes
0
°C/°F
dE
0
15
3/6
60
15
10
EAL
CL
5
AL
CL
0
0/32
2/4
rP
rE
no
6.0
8/46
20
rt
0
c_n
30
2/4
2
30/60
30/60
15
30
y
0
1
rP
iP
no
321
ntc
--
--
6/6