Dixon Bayco Petunjuk Instalasi - Halaman 5
Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Peralatan Industri Dixon Bayco. Dixon Bayco 5 halaman. Locking handle kit
Juga untuk Dixon Bayco: Petunjuk Pemeliharaan & Pengoperasian (4 halaman), Petunjuk Pemeliharaan & Pengoperasian (4 halaman), Petunjuk Pemeliharaan & Pengoperasian (10 halaman)
FloTech Thermo-Optic Sensors and Thermistor Dummy
Retain Sensor
FloTech model FT152 is designed to fit into a ½ NPT half coupling
welded into the bottom of each compartment. The mounting location
should be the lowest point of the tank. The collar should not protrude
more than ¾ inch outside the tank and flush with the inside of the
tank when possible. FloTech supplies a ½ NPT weld coupling with
each sensor. The coupling requires a 1 1/8" diameter hole cut in the
bottom of the tank. After the welded coupling has cooled, install the
sensor using pipe sealant or Teflon tape to lubricate and seal the
threads. Check thread engagement to ensure the retain sensor
prism tip is set deep enough into the tank as to clear weld collar.
DO NOT USE THE BODY OF THE SENSOR TO TIGHTEN!
Dixon Bayco Warranty
For complete warranty information, please refer to the latest
Dixon catalog.
THERMO-OPTIC SENSORS
Rev: Dec 2008
5