1) Safety Precautions
What you must do:
• Read these instructions before using
your air compressor.
• Ensure the compressor has been
installed, electrically connected and
piped in by a properly qualified person.
• Ensure the compressor is kept upright
at all times.
What you must not do:
• Do not attempt any maintenance on
the compressor until it has been isolated
from the power supply.
• Do not attempt any work on the
compressor until the air receiver and
pipe work systems are depressurised.
• Compressed air is dangerous if misused
and can prove fatal. Avoid any bodily
contact with compressed air.
• During operation the motor will
become quite hot to the touch. Avoid
contact to prevent burns. • Never
tamper with the pressure relief valve.
• Never lubricate the oil free motor or
pump assembly; this will cause severe
damage.
• Never obstruct cooling fans or outlet
vents.
Electrical Connections
Where applicable, compressors are supplied with a moulded plug in accordance with
national standards.
Never remove the moulded plug.
The use of extension cables is not recommended as this may cause voltage drops
which can result in damage to the motor.
220v/50Hz models wired in accordance
with European Standard -
Blue = Neutral
Brown = Live
Yellow/Green Stripe = Earth
2) Siting The Compressor
What you must do:
• Provide adequate protection from the
weather.
• Site the compressor level in both
planes.
• Allow access for maintenance all
around the compressor.
• Site in a dry area, avoiding damp or
humid conditions. The site must be dust
free, well ventilated and have a cool
ambient temperature. 0 to 40°C should
be regarded as the minimum and
maximum allowable ambient.
• Ensure there is a minimum of 30cm
clearance around the compressor
What you must not do:
• Enclose the compressor or allow hot air
generated by the motor to recirculate
around the compressor.
• Restrict air flow around the end cover
ventilation grilles
damage may occur.
2