AIMS PWRINV150W Panduan Pemilik - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Inverter AIMS PWRINV150W. AIMS PWRINV150W 7 halaman. 150 watt
Notes
• Loose connections can result in severe decrease in voltage, which may cause
damage to the component or product you wish to operate.
• The audible alarm may make a momentary "chirp" when the inverter is turned
ON(I) or OFF(O). This same alarm may also sound when the inverter is being
connected to or disconnected from the 12-volt power source. This is normal.
• If the GREEN LED Indicator Light blinks when you first turn the inverter ON(I),
this may indicate an interruption of the power supply. Simply turn the inverter
OFF(O) and remove the 12-volt power cord from the cigarette lighter socket
(or other 12-volt power source). Firmly re-insert the 12-volt power cord, then
turn the inverter ON(I) again. Or, if you are using the cables, try removing and
reconnecting the clamps. If this does not fix the problem, try using a different
12-volt power source or check the cigarette lighter fuse.
• If using an appliance above 180-watts, you must use the supplied battery clips
for direct connection to the 12-volt power source.
• If using more than one appliance, do not exceed a combined total of 400 watts.
Source of Power
Most automobile and marine batteries will provide an ample power supply to
the inverter for 30 to 60 minutes even when the engine is turned off. Actual
time may vary depending on the age and condition of the battery and the power
demand being placed on it by the equipment being operated.
If you decide to use the inverter while the engine is off, we recommend that you
start the engine every 30 to 60 minutes and let it run for approximately 10
minutes to recharge the battery. It is also recommended that the device
plugged into the inverter be turned OFF before starting the vehicle engine.
Although it is not necessary to disconnect the inverter when starting the vehicle
engine, it may momentarily cease to operate as the battery voltage decreases.
When the inverter is not supplying power, it draws very low amperage from the
battery. It is recommended that the inverter always be disconnected when not
in use.
Blown Automotive Fuses
Depending on the make and model of your automobile, running the power
inverter near full capacity from your cigarette lighter socket may result in a
blown automotive cigarette lighter fuse. This fuse will need to be replaced with
the same type and size fuse. A blown automotive cigarette lighter fuse will not
cause damage to your vehicle's wiring.
To avoid blowing an automotive fuse, do not operate the power inverter over
180 watts from your cigarette lighter or other 12-volt power port. You should
connect the inverter directly to the 12-volt power source using the supplied
battery clips.
AIMS Power Inverter 150W
5
Blown Inverter Fuses
Your power inverter is equipped with a 40-amp spade type fuse. With
reasonable care, it should not be necessary to replace this fuse.
In general, most blown fuses are the result of reverse polarity hook up of the
inverter to a 12-volt power source (positive to negative and/or negative to
positive). If the fuse happens to blow, disconnect the appliance or equipment
from the inverter immediately. Find the source of the problem, repair it and
then install a new fuse of the same type and size located on the rear panel of the
inverter.
Note: Always disconnect the power inverter from the 12-volt power source and
make sure the inverter is turned OFF before replacing the fuse.
Safety and Usage Precautions
• For best operating results, place the inverter on a flat surface
• Keep inverter dry. Do not expose inverter to rain or moisture.
• DO NOT operate the inverter if you, the inverter, the device being operated, or
any surface that may come into contact with the inverter are wet. Water and
other liquids can conduct electricity, which may lead to serious injury or death.
• Avoid placing the inverter on or near heating vents, radiators or other sources
of heat. Do not place or use the inverter in direct sunlight. Ideal air
temperatures should be between 50° and 80° F .
• In order to properly disperse the heat generated from the inverter while it is
operating, keep the inverter well ventilated. Keep the area surrounding the
inverter clear while in use.
• Do not use the inverter near flammable materials. Do not place the inverter in
areas such as battery compartments where fumes or gases may
accumulate.
Inverter Protection Features
• Short Circuit Protection. The inverter will automatically shut down until
short is removed.
• Low Voltage Alarm. An alarm will sound when the voltage from the battery
discharges to 10.5 +/- 0.5 volts DC. This is an indication that the battery needs
to be recharged.
• Over Voltage Protection. The RED LED Indicator Light will illuminate and
the inverter will automatically turn itself off when the input exceeds
16.5 +/- 1 volt DC.
Owner's Manual
6