Any electrical connections should be performed by a certified electrician in accordance with all electrical codes.
Aqua Elite 50 systems are universal voltage, meaning the unit will work on 115 or 230VAC without any
internal switching. When locating the power source, make sure that when the pump and motor shuts off, the
Aqua Elite 50 will too. The ideal source is the timer box. If no timer box exists, the
unit can use the pump motor as its power source. In other words, the electrical
connection should be such that the Aqua Elite 50 is supplied power only when the
power is supplied to the pool filter/circulation pump.
A permanent ground bonding connector is provided on this unit and should be used to
connect a minimum 12 AWG solid copper wire conductor to any metal equipment,
metal enclosures of electrical equipment, metal water pipe, or conduit within five (5)
feet of the unit.
When locating the power source, the unit should turn on and off when the pump and motor does. The best location is the
pool's timer box. If no timer box exists, you can use the pump motor as its power source by removing the back plate.
The unit will automatically work on 115VAC or 230VAC
Below is an example of connecting the control box to a timer box. In this example an Intermatictm timer box is used.
Although most timer boxes are similar they are not exactly the same, please take care when using the provided
information.
230 VAC Operation:
Connect the black (3 stranded) wire cable to the 230 VAC timer box by splicing the 3 wires and connecting the black and
white wires to the LOAD side on the timer box. It makes no difference which colored wire goes to the two load screws.
Connect the green wire to GROUND. When installed properly, the unit should come on and off when the pool pump
goes on and off.
115 VAC Operation:
Connect either the white wire or the black wire to the LOAD side on the timer box. It makes no difference which colored
wire goes to the two load screws. Connect the green wire to ground. When installed properly, the unit should come on
and off when the pool pump goes on and off.
I). ELECTRICAL
J). CHOOSING THE POWER SOURCE
Connecting the control box to the timer box
TO R-50
CONTROL BOX
TO R-50
CONTROL BOX
8