circumference to prevent the loop wire from rising up while the sealant is poured and
curing.
Many different types of loop sealant are now available. Single part types are the easiest to
apply since no mixing is required, but they also tend to be more expensive in terms of linear
feet of saw slot filled. When applying the sealant, make sure that it is able to sink to the
bottom of the slot and completely encase the loop wire. The wire should not be able to
move when the sealant has set. Ensure that there is enough sealant to completely fill the
slot; if possible the sealant should protrude slightly above the surface of the pavement so
that small rocks or other debris cannot collect in the slot.
The sealant manufacturer instructions concerning setting time should be noted especially
when determining the length of time to wait before allowing vehicles to cross the loop area.
Consult the Eberle Design web site at
www.EDItraffic.com
for further application
information regarding loop design.