will whistle continuously and the green light is off, red light is on. Please turn
off the inverter, and continue using it after the temperature goes back to
normal naturally. Meanwhile find out the factors causing the fault, such as
ventilation, ambient temperature, vent, load power etc. It can avoid similar
things from happening again.
**NOTE** When the inverter is in the OFF position, the inverter doesn't consume
battery current.
HI-POT TESTING OF DC to AC Inverter
Most of our AC inverters are Hi-Pot test and can pass a High Voltage Dielectric
Withstand Test. The voltage applied to the control is usually equal to 1,000 volts, plus
two times the line voltage rating of the inverter. Therefore, the standard hi-pot voltage
for 115 VAC inverter is 1,250 VAC. For 230 VAC or dual voltage inverters, the hi-pot
voltage is 1,500 VAC. This Aims power inverter is hi-pot tested before it leaves the
factory. Hi-Pot testing is used to detect any electrical leakage between live metal
components and the frame of the machine that is connected to earth ground. This
helps prevent electrical shock to the user of the equipment should a live component
touch the frame and the user touch the frame and ground at the same time.