COPPER/SILVER IONIZATION SYSTEM: the copper anode (cell)
should be checked every 6 months and will last approximately 2yrs
under normal conditions. Additional cells can be purchased from your
authorized dealer.
Cleaning the anode (cell): deposits can be removed using a smooth
metal file and water. The surface does not have to be polished;
simply remove any traces of oxidation and other sediments.
Replacing the anode (cell): shut off the circ pump valve and
spa system pack valve or drain the spa's water. Turn old cell
counterclockwise to release it from the tee. If there is not enough
room unthread the spa system pack/heater union adjacent to the
anode tee so the plumbing can be moved. Reverse these steps
after threading the new cell by hand into the tee. To ensure even
wearing of the electrodes, turn until the two prongs are oriented so
the water flows between them.
Cleaning the Controller: The housing of the controller is made from
a durable PVC plastic. Clean the outside with mild soap and water,
rinse and dry with a soft cloth. Do not use any type of household or
abrasive cleaner.
MAGNETIC FIELD: no maintenance required!
UVC SANITIZER: the UV bulb or lamp should be replaced every 12-18
months even if it is still working to ensure optimum performance. See
manufacturer's manual for replacement details.
OZONE GENERATOR: no maintenance required! Ozone generators will
wear out after a few years. Replace as needed. (Note: the UV and Ozone
generator are combined in a single component. The Ozone generator is
not replaceable separately)

EQUIPMENT MAINTENANCE