ArtFox Lightning FLEX BEAM V8 Panduan Pengguna - Halaman 11
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Lampu Banjir ArtFox Lightning FLEX BEAM V8. ArtFox Lightning FLEX BEAM V8 13 halaman.
6. DMX Connection
1. Connect the fixture together in a "daisy chain" by XLR plug cable from the output of the fixture
to the input of the next fixture. The cable cannot be branched or split to a "Y" cable.
Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the
signal and shut down the system
2. The DMX output and input connectors are pass-through to maintain the DMX circuit when one
of the units' power is disconnected.
3. At last fixture, the DMX cable has to be terminated with a terminator to reduce signal errors.
Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug
and plug it in the DMX-output of the last fixture.
4. Each lighting fixture needs to have an address set to receive the data sent by the controller.
The address number is between 0-511 (usually 0 & 1 are equal to 1).
5. 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
11