AIMS Power PWRIG150048120S Panduan Pengoperasian - Halaman 14

Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Inverter AIMS Power PWRIG150048120S. AIMS Power PWRIG150048120S 16 halaman.

AIMS Power PWRIG150048120S Panduan Pengoperasian
 General problems
Audio system noise:
Noise may be generated from the speakers or amplifier when using the inverter to power
low-grade stereo systems and large portable radios. This is due to the interference between the electricity and current running
through each device. You are hearing the RF generated by the inverter.
TV interference:
the operation of this inverter may cause interference in receiving specific TV channels; in this case
perform the following procedure's to try to resolve the problems.
Audio, TV and wireless devices shall be installed in an area as far as possible away from the inverter. Try installing a line
filter on affected device.
 Cautions during use
 For normal operation, devices with excessive loads applied momentarily such as refrigerators, air conditioners, electric
motors, hand tools Etc. Should be within 60% of the maximum output capacity of this inverter. Check the capacity of
this inverter as well as the capacity of the intended devices to be used.
 When the rated continuous capacity of the motor is equal to or greater than the rated capacity of the inverter, operation
of the intended device may not be available due to the inverters lack of surge ability. (Example. A 2000 watt motor
with a 2000 watt inverter, the startup of the motor may be 6000 watts and cause the inverter to fail.)
 Devices using heaters will increase the temperature of the inverter drastically. When using devices like this make sure
to provide proper ventilation for the inverter. Improper ventilation will cause inverter shutdown and malfunction
resulting in irreversible damage.
 Audio and video devices shall be used within the maximum power rating of the inverter. If the rating capacity is
exceeded there will be a momentary cut-off. For safe operation use 75%-80% of the listed capacity.