Altronix AL1012ULM Panduan Instalasi - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Catu Daya Altronix AL1012ULM. Altronix AL1012ULM 17 halaman. Multi-output access control power supply/chargers
Juga untuk Altronix AL1012ULM: Panduan Instalasi (17 halaman), Panduan Instalasi (17 halaman)
![Altronix AL1012ULM Panduan Instalasi](/uploads/products/server2/847322/847322.jpg)
Fig. 1 - AL300ULM and AL400ULM
CAUTION: De-energize unit prior to servicing. For continued protection
against risk of electric shock and fire hazard replace fuses with the same type
and rating (see marking on the board). Do not expose to rain or moisture.
Wire Strap
(from Enclosure
to Door)
Fig. 1a
Earth
Ground
NC
C NO
NC C
NO
Battery & AC
Supervision Circuit
(power-limited)
Fig. 1b
J1
AC Delay
Keep power-limited wiring separate from non power-limited.
Use minimum 0.25" spacing.
CAUTION: Optional rechargeable stand-by batteries must match
the power supply output voltage setting.
- 6 -
115VAC power mains
non power-limited
Class 1
AC Delay
+ BAT -
+ DC -
Battery Connections
non power-limited
Optional Rechargeable
Stand-by Battery
DC Outputs to devices
ON
(power-limited)
Optional Rechargeable
Stand-by Battery
SW1
Fig. 1c
OFF - 24V
ON - 12V
M Series Installation Guide