AIMS Power PWRIX120012SUL Buku Petunjuk - Halaman 6

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Inverter AIMS Power PWRIX120012SUL. AIMS Power PWRIX120012SUL 13 halaman. Dc to ac pure sine power inverter with automatic transfer switch

requirement 3-5x its running wattage. In this example, 960 watts * 3 = 2880 watts
needed from the inverter so don't size your inverter too small.
2. Battery operating time depends on battery capacity and load. The formula for
operating time is: battery capacity divided by the value of the load divided by
battery voltage times 1.10%. For example, using the numbers from above, the
battery specification is 12V, 200Ah capacity and the load is 1000W. Take battery
capacity 200Ah / 91.6 amps = 2.18 hours of run time if you fully deplete the
battery. This is NOT recommended. Deep cycle batteries last longer when they
are only depleted to 50% of capacity.
F. CONNECTION
1. Grounding
The power inverter has a terminal on the rear panel marked " Grounding "or "≡".
This is used to connect the chassis of the power inverter to ground. The ground
terminal has already been connected to the ground wire of the AC output
receptacle through the inverter.
The ground terminal must be connected to the ground wire, which will vary
depending on where the power inverter is installed. In a vehicle, connect the
ground terminal to the chassis of the vehicle. In a boat, connect it to the boat's
ground system. In a fixed location, connect the ground terminal to earth.
2. Battery Terminals
Before you connect the battery cables, make sure the power switch is in the off
position. Connect Red (+) battery cable to Red (+) inverter terminal. Connect
Black (-) battery cable to Black (-) inverter terminal. Connect Red (+) battery
cable to Red (+) battery terminal. Connect Black (-) battery cable to Black (-)
battery terminal. Alligator clamp cables may be used but only to connect to the
battery. Do not use clamps on inverter terminals. Alligator clamps are not a
permanent solution. You may see a spark during connection. Do not reverse the
polarity. This may damage the inverter and void warranty.