ARTHUR HOLM DynamicTabLift Panduan Pengguna - Halaman 11

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Sistem Pengangkatan ARTHUR HOLM DynamicTabLift. ARTHUR HOLM DynamicTabLift 20 halaman.

ARTHUR HOLM DynamicTabLift Panduan Pengguna

AHnet PROTOCOL

Communications protocol
COMMUNICATION
CONNECTION
WIRING
Speed and configuration
BAUD RATE
DATA BITS
PARITY
STOP BITS
Wiring Diagram
1. Data TX +
2. Data TX –
3. Data RX +
4. NC
5. NC
6 .Data RX –
7. NC
8. NC
Connection
PINS 1 & 2
PINS 3 & 6
Protocol to control the unit by addressable RS422 bus.
You can connect up to 30 units on the same RS422 bus.
You can use an AH Interface Ethernet, to control the RS422 bus.
The units should have a set address and the address must start by 1.
Maximum cable length between ends: 500 m/1640 ft.
11
RS422
RJ45
CAT-6
38400
8
NONE
1
The units respond
The units receive instructions
RJ-45