The Altronix AL1002ULADA is an extremely cost effective 10 amp remote power supply/battery charger. It may be con-
nected to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit
(NAC such as strobes and horns) expansion support to meet ADA requirements. It also provides auxiliary power to support
system accessories. The unit delivers electronically regulated and filtered 24 volt power to Class B, Style W, Y or Class
A, Style Z NAC loop circuits. Additionally, a separate 1.0A auxiliary output for four (4)-wire smoke detectors is available.
The 10 amp max. alarm current can be divided between the four (4) outputs for powering NAC devices. Each output is
rated at 2.5 amp max., and can be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All
outputs may be programmed for Input to Output Follower Mode (output will follow input). In non-alarm condition inde-
pendent loop supervision for Class A, Style Z and/or Class B, Style W, Y FACP NAC circuits is provided. In the event of
a loop trouble, the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble
output terminals (NC, C, NO) which are used to indicate general loop/system trouble. A common trouble input is provided
for optional NC (normally closed) devices to report trouble to the FACP. Two (2) FACP signaling outputs can be employed
and directed to control supervision and power delivery to any combination of the four (4) outputs.
Note: The information in this document is valid for models AL1002ULADA and AL1002UL2ADA. Model AL1002ULADA
is equivalent to model AL1002UL2ADA.
Agency Listings:
• UL Listed Control Units for Fire Protective
Signaling Systems (UL 864).
• MEA - NYC Department of Buildings Approved.
• CSFM - California State Fire Marshal Approved.
• FM - Factory Mutual Approved.
• NFPA 72 Compliant.
Input:
• Power input 120VAC 60 Hz, 5.0 amp.
• Two (2) Class A, Style Z or two (2) Class B,
Style W, Y FACP inputs.
• Two (2) NC dry contact trigger inputs.
Output:
• Class 2 Rated power-limited outputs.
• 24VDC @10 amp max total alarm current.
• 2.5 amp max current per output.
• Separate 1.0 amp auxiliary output.
• Programmable supervised indicating circuit outputs:
Four (4) Class B, Style W, Y or Two (2) Class A,
Style Z or One (1) Class A, Style Z and Two (2) Class B,
Style W, Y (see Application Guide).
• Thermal and short circuit protection with auto reset.
Battery Backup:
• Built-in charger for sealed lead acid or gel type batteries.
• Automatic switchover to stand-by battery when
AC Fails.
• Zero voltage drop when switching over to
battery backup.
- 2 -
AL1002ULADA - NAC Power Extender
Overview:
Specifications:
Supervision:
• AC fail supervision (form "C" contact, 1 amp / 28VDC).
• Instant local AC trouble reporting relay
• Battery presence and low battery supervision
Visual Indicators:
• Input and output status LED indicators.
Special Features:
• 2-wire horn/strobe Sync mode allows audible
• Sync protocols include Potter/Amseco, Faraday,
• Temporal Code 3, Steady Mode, Input to Output
• Compatible with 12VDC or 24VDC fire panels.
• Output loop supervision steered to input 1 or input 2.
• Signal circuit trouble memory (helps identify
• Common trouble input and output.
• Ground fault detection.
• Unit includes power supply, red enclosure, cam lock,
Enclosure Dimensions (approx. H x W x D):
15.5" x 12" x 4.5" (393.7mm x 304.8mm x 114.3mm).
Factory set for 1.5 hours with optional 30 seconds
delay setting (field selectable).
(form "C" contact, 1 amp / 28VDC).
(form "C" contact, 1 amp / 28VDC).
notification appliances (horns) to be silenced
while visual notification appliances (strobes)
continue to operate.
, System Sensor
Gentex
®
Follower Mode (maintains synchronization of
notification appliances circuit).
intermittent loop problems).
and battery leads.
, and CooperWheelock
®
.
®