Altronix eBridge100RM Panduan Instalasi - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Transceiver Altronix eBridge100RM. Altronix eBridge100RM 4 halaman.

Altronix eBridge100RM Panduan Instalasi
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes
and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
eBridge100ST and eBridge100RM are not intended to be connected to outside plant leads and should be
installed indoors within protected premises. eBridge100ST and eBridge100RM are intended for indoor use only.
Note: The eBridge100RM and eBridge100ST are a paired set and must be used together.
1. eBridge100RM installation:
a. Secure unit to the desired mounting surface with a proper fastening device utilizing the unit's mounting
hole (Fig. 2a, pg. 4). Unit should be mounted in the proximity to ethernet switch/network, NVR or video server.
Note: When installing more than one (1) eBridge100RM, please allow at least 1" (25mm) distance
between the receivers.
b. Connect structured cable from Ethernet midspan or endspan device to RJ45 jack marked [PoE Input]
(Fig. 2, pg. 4).
c. Connect Coax cable to the BNC connector marked [Coax] (Fig. 2, pg. 4).
2. eBridge100ST installation:
a. Secure unit to the desired mounting surface with a proper fastening device utilizing the case's
mounting hole (Fig. 2a, pg. 4). Unit should be mounted in the proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 2, pg. 4).
c. Connect Coax cable to the BNC tether cable marked [Coax] (Fig. 2, pg. 4).
Note: This kit is designed to accommodate Megapixel, HD720, HD1080, and VGA (SD) cameras. It is important to
note that some high resolution and high frame rate cameras may demand faster headend processing ability, such
as a PC graphics card, to present a quality image. If the headend processing equipment's speed is insufficient,
the image may show pixelation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate
and resolution may be reduced to accommodate system equipment.
Parameter
Connections
Input power
requirements
Indicators
Environmental Conditions
Regulatory Compliance
Weights (approx.)
*Note: Caution: once PoE connection is established between eBridge100RM and eBridge100ST, disconnection
from eBridge100ST will not disable the PoE output voltage on the eBridge100RM. Although the eBridge100ST can
be reconnected, caution should be taken not to connect coax wiring from eBridge100RM to any non-PoE device.
eBridge100STR Installation Guide
Installation Instructions:
Technical Specifications:
Description
BNC for Coax link.
Midspan or endspan port connected. PoE compliant to IEEE 802.3af (15W) and
PoE+ compliant to IEEE 802.3at (30W).
Yellow (RJ45 connector):
Green (RJ45 connector):
Yellow:
Operating Ambient Temperature (UL60950-1):
eBridge100RM:
eBridge100ST:
Relative Humidity:
Storage Temperature: – 20ºC to 70ºC (– 4ºF to 158ºF).
Operating Altitude:
UL/cUL Listed for Information Technology Equipment (UL 60950-1).
CE European Conformity.
Product: 0.4 lb. (0.18 kg) | Shipping: 1 lb. (0.45 kg).
On - Link, Off - No Link, Blinking - Activity.
On - 100Base-TX, Off - 10Base-T.
PoE Active.
– 20ºC to 49ºC (– 4ºF to 120.2ºF).
For 15W:
– 40ºC to 75ºC (– 40ºF to 167ºF).
For 30W:
– 40ºC to 60ºC (– 40ºF to 140ºF).
85%, +/– 5%
– 304.8 to 2,000m.
- 3 -