TROUBLESHOOTING
B - If the plow did not operate during the jumper test, check the small 10amp in line fuse down by the pump
motor.
If the fuse is ok remove the pump guard and with the use of a voltage tester con
main terminal where the red power lead is connected on the solenoid. If there is 12V supply try the next test to
see if the control wire is defec ve. Remove the cap on the main power feed and the green control wire from the
solenoid. Jumper from main power to the open terminal.
If the pumps runs there is an issue in the control wire on the plow.
If the pump does not run, try this next step to test the solenoid
If the motor runs the solenoid is faulty, if the motor does not run the motor is faulty.
En.12
DK2 Everest R-3 man.
that there is 12volts on the