 Please do not install a smoke alarm in a humid environment, such as a bathroom. Water vapor
enters the detection unit of the smoke alarm, causing false alarms and malfunctions. Make
sure the smoke alarm is at least 3 meters away from the humid environment.
 Do not install this product in a place where there may be a lot of dust. Dust may enter the
detection unit, causing false alarms.
 Do not install this product in a place with high air circulation. Such as the air conditioner.
Strong air flow will blow away the smoke, causing the alarm to fail.
 Do not install this product in places where air circulation is too weak, such as the roof. The
non-flowing air can hinder the spread of smoke, causing the alarm to fail.
 Do not install this product near strong light sources, such as fluorescent lamps. Due to
electrical characteristics, strong light can cause false alarm on smoke alarms.
 Do not install this product near metal sources. Strong metals will absorb wireless signals,
causing wireless functions to fail.
Warning : Please do not stop the false alarm by powering off. The smoke alarm stops the
Warning
Warning
Warning
alarm after the smoke in the detection unit has dissipated. If you want to stop the alarm
immediately, you can speed up the scattering of smoke inside the detection unit, such as
blowing.
4. 4. 4. 4. INSTALLATION GUIDE
INSTALLATION GUIDE
INSTALLATION GUIDE
INSTALLATION GUIDE
This product needs to be installed on the ceiling. You can refer to Chapters 3 of this article to
determine where to install the product. Please follow the steps below to install.
1. Draw a 15 cm line at the location you want to install.
2. Remove the back cover from the sensor.
3. Align the two elongated holes on the back cover with the previously drawn lines and mark the
two long holes on the line. .
4. Using a 5 mm drill bit, make two holes in the position where the long hole was previously
marked, then insert the two plastic expansion tubes into the hole, making sure that they are
completely immersed. Please be careful not to let the dust generated by the punch enter the
smoke sensor when punching.
5. Align the long hole on the back cover with the expansion tube and then screw the screw into the
expansion tube from under the back cover.
6. Install the battery into the smoke sensor. For details, please refer to the "Start up" section.
7. Fasten the smoke sensor to the back cover.
8. Press the test button on the alarm. If you hear the sound, it means the smoke sensor has
started working.
AR/DS/Doc-2010009
TECHNICAL DATA
TECHNICAL DATA
TECHNICAL DATA
TECHNICAL DATA
[email protected], support technis
, support technis http://www.artra.co.id/
, support technis
, support technis
WIRELESS SMOKE
DETECTOR CM90
http://www.artra.co.id/
http://www.artra.co.id/
http://www.artra.co.id/
3 |
P a g e