ARTRAY ARTCAM-130SWIR-CL Buklet Instruksi - Halaman 11

Jelajahi secara online atau unduh pdf Buklet Instruksi untuk Kamera IP ARTRAY ARTCAM-130SWIR-CL. ARTRAY ARTCAM-130SWIR-CL 12 halaman. Camera link output near infrared (ingaas) camera

6.3. Camera function

6.3.1.

Camera function list

The functions of the camera are as follows.
No
Item
1
Reset
2
Shutter Speed
3
Analog Gain
4
Digital Gain
5
Offset
Black Level
6
Correction
7
Sensitivity Correction
Defect Pixel
8
Correction
6.3.2.

Camera function block diagram

※ Please refer to "ARTCAM-130SWIR-CL_Camera Link Setting Manual" for more details about Camera Link settings.
Default
Setting range
value
-
-
1~1000000
100
Low/Mid
Low
0~255
32
(0~7.97times)
0~255
0
ON/OFF
ON
ON/OFF
ON
ON/OFF
ON
- 11 -
Remarks
Initialize the camera
Changing the shutter speed
Shutter speed [μsec] = set value * 100
Cell capacity selection of sensor
(High Gain can not be selected)
Gain magnification = set value * 1/32
ON / OFF selectable
Offset = set value * 64 (14 bit value)
ON / OFF selectable