Alvarado Supervisor 500 Panduan Petunjuk Instalasi - Halaman 11
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Pintu putar Alvarado Supervisor 500. Alvarado Supervisor 500 19 halaman. Barrier-free optical counting turnstile
Configuring the SU500
To configure the SU500, you will need to modify the turnstile configuration file ModelConfig.txt. To access and modify this file, you
will need a computer and UltraVNC Viewer remote desktop software. UltraVNC Viewer is located on the File Management CD that
was provided with the turnstile. If you are unable to locate, or have misplaced, the File Management CD, contact Alvarado Technical
Support.
Computer Requirements
•
Operating System - Windows XP / Windows Vista / Windows 7 / Windows 8
•
.NET Framework 4.0 or greater
•
CD- / DVD-ROM drive
Installing UltraVNC Viewer
1.
Insert the File Management CD into the CD/DVD drive on the computer.
2.
Navigate to X:\File Management Utility CD\UltraVNC Software.
3.
Double-click the UltraVNC_1.0.9.6.2_Setup icon to begin the installation.
4.
During the installation process, go with the default selections with the exception of the Select Components screen, in which
UltraVNC Viewer Only should be selected.
5.
Follow the installation prompts until the installation is complete.
Before making any configuration changes, please read the following brief descriptions of the two SU500 operating modes.
Operating Mode
Count
No Passage
Page 20
For Assistance: [email protected] +1 (909) 591-8431
SU500 Installation Instructions
Description
A count is generated each time a user
completes a passage. Count mode can
be either single direction or bi-directional.
Bi-directional count mode is the default
configuration. This is the default operating
mode.
No passage is allowed. A passage attempt
sets off a violation alarm. If a user passes
through the lane, a count is still generated in
order to track no passage violations.
SU500 Installation Instructions
Configuring the SU500 (cont.)
Connecting a Computer to the Turnstile
1.
Locate the Ethernet port on the main turmstile controller [Figure 20].
2.
Connect the Ethernet cable from the computer to the Ethernet port.
3.
Launch UltraVNC Viewer.
4.
Enter the turnstile IP address in the VNC Server field [Figure 22]:
•
If this is a newly installed or non-networked turnstile, enter the factory default turnstile IP address: 192.168.0.100.
•
If the turnstile has already been configured with a facility network IP address, enter that network IP address.
Click the Connect button.
5.
PUD1456R5-0
PUD1R5-0
Figure 22
UltraVNC Viewer
For Assistance: [email protected] +1 (909) 591-8431