DNF Controls 4000CL-L Panduan Pengguna - Halaman 5
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Pengontrol DNF Controls 4000CL-L. DNF Controls 4000CL-L 19 halaman. 400 clip fast access system using louth protocol
3.
SYSTEM INSTALLATION
a.
Plug one end of a 9-conductor, RS422 serial cable into the VTR 1 (2, 3 or 4) connector
on the rear of the ST300. Plug the other end of the cable into the REMOTE connector on
the Video Server.
b.
Connect the supplied POWER SUPPLY, APX#4108, into the POWER connector on the
rear of the ST300. Plug the Power Supply into an outlet, 90 VAC – 240 VAC.
c.
Assign logical Louth ports to ST300's VTR's connectors.
1)
2)
3)
4)
5)
6)
7)
8)
d.
Check SETUP MENU prior to using the ST300 to confirm proper Record mode and other
User settable modes.
Installation is complete.
5
4000CL-L, Vs.2.1, 400 Clip Fast Access System, Louth Protocol
Press [MENU].
Turn the wheel until VTR Louth Address is displayed.
Press VTR[1], VTR[2], VTR[3] or VTR[4] to select VTR.
Assign a Louth Port address by entering a style number 0-9 using the numeric
keypad. (0 turns that channel OFF.)
The second line of the display will show "Input=Enter, Out=ESC."
Press [ENTER] to select an Input Port.
(A "-" will appear in front of the selected number.)
OR
[ESC] to select an Out Port.
Repeat steps 3 - 6 above to assign Louth Address to ALL ST300 VTRs you
want to use.
Press [ESC] to exit the MENU mode.