3200ET Remote Meter
Installation and Start-Up Procedures (Cont'd.)
7. In normal operation the Time Of Day, and if flow meter equipped, Volume Remaining Displays alternate being
viewed. Set the Time Of Day Display by depressing the Up or Down Set Button to the correct time. (See Fig. 1)
For Example:
12:59 A.M.
(Valve in Service)
8. Remote Meters Only: The Volume Remaining Display is the volume of water (in gallons) remaining prior to
regeneration, including any reserve capacity. Without any water usage the Meter Arrow should be either off or on
but not changing. Open a soft water tap. The Meter Arrow should begin flashing at a rate that varies with flow rate.
Close the tap after 3 - 5 gallons of water flow.
For Example:
25 Gallons Of Water
Remaining
(Valve in Service)
(No Water Flow)
(Volume is below
reserve capacity,
Reserve Arrow
Flashing)
Printed in U.S.A.
Figure #1
For Example:
0 Gallons Of Water
Remaining
(Valve in Service)
(Water Flowing, Meter
Arrow Flashing))
(Volume is below
reserve capacity,
Reserve Arrow
Flashing)
Page 3