Control Operation (Cont'd.)
Control Operation During A Power Failure
During a power failure all control displays will be turned off and regeneration cycles delayed. The control will otherwise
continue to operate normally until line power is restored or battery backup power is lost.
1. If battery backup power is never lost during a power outage, the control will continue to operate normally, without
the loss of data, until line power is restored.
2. If battery backup power is lost during a power outage, the control will store the current Time Of Day, Volume
Remaining, Regeneration Signal Status, and various diagnostic displays. These stored displays will then be used
upon line power restoration until updated ones are created. To indicate this type of failure, the control will flash the
current Time Of Day Display to indicate that this display and the Volume Remaining Display may not be correct.
Control Operation During Regeneration
During Regeneration a special regeneration display will take the place of either the Time Of Day or Volume Remaining
Display. This display will contain the number one (to indicate only one regeneration signal is being sent) and the signal
time remaining.
1. First the Regeneration Arrow turns on. Then the display below appears to indicate that a Regeneration Signal is
being sent and how long it will be.
For Example:
(Regeneration Signal has started)
(6.0 minute regeneration signal to be sent)
(Regeneration Arrow On)
2. As time passes the countdown display will decrement in tenths of minutes until the time remaining reaches zero.
When this occurs the control will return immediately to Service
For Example:
(Regeneration Signal has started)
(3.2 minutes remain for signal)
(Regeneration Arrow On)
3. Pushing the Extra Cycle Button during a regeneration signal will immediately return the control to Service.
4. Pushing the Up or Down Set Button during a regeneration signal will adjust the signal time remaining. Actual
Regeneration Signal programming will not be changed.
Printed in U.S.A.
Regeneration
Signal
Regeneration
Signal
Page 7