2.11. Digital Outputs

There are three digital outputs on NxtG-V. All are of open drain type and the maximum
drain current is 150 mA. Each output has the built-in over current PTC resettable fuse.
Logical status
Enable
Disable
Digital Output Internal Drive Circuit
Electrical Characteristics of Digital Outputs
Electrical characteristics
<1.5V @150 mA
Open drain
Typical Connection with Relay