CONDITIONED POWER DISTRIBUTION
PD1 1LV
1
Light Switch - activates rack illumination. Choose HI or LOW intensity
2
Light Tubes - illuminates up to 25 rack spaces or over 3 feet
3
Digital Voltmeter Readout - displays incoming line voltage
4
Circuit Breaker—resetable 15 amp thermal circuit breaker
5
Outlet Switch - lighted power switch activates protection and filtration to all black outlets and front panel outlets
6
Front Panel Outlet - convenient, filtered, protected and switched outlet
7
Power Cord - Six foot heavy duty U-grounded 14-gauge power cord
8
Ivory Outlets - unswitched outlets with continuous power available. Circuit breaker protected.
9
Black Outlets - EMI/RFI filtered, spike/surge protected and switched outlets
PD11LV Operating Instructions:
1. Install in a standard 19" rack or free standing position.
2. Connect Power Distribution power cord (#7) into standard 120V wall outlet.
3. Plug sensitive electrical equipment into conditioned black outlets (#9) or (# 6).
4. Move power outlet switch (#5) to "ON" position to provide power and protection to electrical equipment.
5. For illumination, pull out light tubes (#2) and move light switch (#1) to "HI" or "LOW" position.
IMPORTANT: Be sure light switch (#1) is in "OFF" position when light tubes are recessed.
6. Digital voltmeter readout (#3) is calibrated to nominal 117V at the factory. No adjustment necessary.
When calibration is required for special applications, an adjustable trimpot is located on the voltmeter readout assembly.
WARNING: Removing top cover is necessary. Adjustment must be done by a qualified individual.
7. Digital voltmeter readout (#3) automatically displays incoming voltage when power cord (#7) is connected. If you wish to
have digital display on only when power switch is "ON", move switch on voltmeter display assembly inside unit to "OFF"
position. WARNING: Removing top cover is necessary. Adjustment must be done by a qualified individual.