Dodge 078289 Buku Petunjuk - Halaman 3

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Peralatan Industri Dodge 078289. Dodge 078289 8 halaman.

Dodge 078289 Buku Petunjuk
RTL Series
A Circulating Oil Inlet Kit is required for each pillow block for the
Cool Lube 2 installation. Install the Circulating Oil Inlet Kit as
shown in the Sleevoil Instruction Manual (see Figure 5).
RTL Circulating Oil Inlet Kit
RTL 2-15/16" thru 5-7/16" Circulating Oil Inlet Kit
RTL 6" thru 12" Circulating Oil Inlet Kit
The user shall provide connection adapters and tee fittings to
connect the supply lines to the circulating oil inlets. A tee fitting
is required at the inlet connection because these pillow blocks
have 2 circulating oil inlets. The tee fitting ensures both oil inlets
receive an equal amount of oil. Flexible connections from the
tee fitting to the oil inlets are recommended (see Table 4 for inlet
connection size).
Table 4–RTL Series
Number of
Circulating
Bore Size
Oil Inlets
and Outlets
2-15/16"
2
3-7/16"
2
3-15/16"
2
4-7/16"
2
4-15/16"
2
5-7/16"
2
6"
2
7"
2
8"
2
9"
2
10"
2
12"
2
Figure 5 - RTL Circulating Oil Inlets
Circulating
Circulating
Alternate Oil
Oil Inlet
Oil Drain
Gauge Hole
NPT Size
Hole NPT
(Female)
Size
3/4 - 14
1 - 11-1/2
3/4 - 14
1 - 11-1/2
3/4 - 14
1 - 11-1/2
3/4 - 14
2 - 11-1/2
3/4 - 14
2 - 11-1/2
3/4 - 14
2 - 11-1/2
1 - 11-1/2
2 - 11-1/2
1 - 11-1/2
2 - 11-1/2
1 - 11-1/2
2 - 11-1/2
1 - 11-1/2
2 - 11-1/2
1 - 11-1/2
2-1/2 - 8
1 - 11-1/2
2-1/2 - 8
RXT Series
A Circulating Oil Inlet Kit is NOT required for these pillow blocks.
The circulating oil inlets are machined into the housing and are
plugged with pipe plugs as shown in the Sleevoil Instruction
Manual (see Figure 6).
Part No.
The supply line should be connected to the two inlets on the
132203
downswing side of the pillow block for base loaded applications,
or to the two inlets on the upswing side for cap loaded
132205
applications.
The user shall provide connection adapters and tee fittings to
connect the supply lines to the Sleevoil circulating oil inlets. A
tee fitting is required at the inlet connection because these pillow
blocks have 2 circulating oil inlets. The tee fitting ensures both
oil inlets receive an equal amount of oil (see Table 5 for inlet
connection size).
Bore Size
NPT Size
2-15/16"
3/4 - 14
3-7/16"
3/4 - 14
3-15/16"
3/4 - 14
4-7/16"
3/4 - 14
4-15/16"
3/4 - 14
5-7/16"
3/4 - 14
6"
3/4 - 14
7"
3/4 - 14
8"
3/4 - 14
9"
3/4 - 14
10"
3/4 - 14
12"
3/4 - 14
3
Table 5–RXT Series
Circulating
Number of
Oil Inlet
Circulating
NPT Size
Oil Inlets
(Female)
2
1/2 - 14
2
1/2 - 14
2
1/2 - 14
2
1/2 - 14
2
1/2 - 14
2
1/2 - 14
2
3/4 - 14
2
3/4 - 14
2
3/4 - 14
2
3/4 - 14
2
1 - 11-1/2
2
1 - 11-1/2
Figure 6 - RXT Circulating Oil Inlets
Circulating
Alternate Oil
Oil Drain
Gauge Hole
Hole NPT
NPT Size
Size
1-1/4 - 11-1/2
1-1/4 - 11-1/2
1-1/4 - 11-1/2
1-1/4 - 11-1/2
2 - 11-1/2
2 - 11-1/2
2 - 11-1/2
2 - 11-1/2
2 - 11-1/2
2 - 11-1/2
2 - 11-1/2
2 - 11-1/2
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
2-1/2 - 8
MN3082