Dodge 200 Series Buku Petunjuk - Halaman 3

Jelajahi secara online atau unduh pdf Buku Petunjuk untuk Peralatan Industri Dodge 200 Series. Dodge 200 Series 16 halaman. Adapter mount and direct mount plummer blocks

Dodge 200 Series Buku Petunjuk
INSTALLATION
USN 200 & 300 Series Direct Mount
1.
Measure the internal clearance of the bearing before
mounting. Place the bearing in an upright position as shown
in Figure 1. Seat the inner ring and roller elements by pressing
down firmly on the inner ring bore while rotating the inner ring
a few times. Position the roller assemblies so that a roller is
at the top most position on either side. Using a feeler gauge
measure the clearance for each side by inserting as far as
possible and sliding over top of roller (Figure 1). Write down
the measured clearance and compare with specifications
Table 3. Note: Do not rotate bearing when moving feeler
between roller and outer ring.
Note: For cylindrical bore direct mount bearings, it
is not necessary to check internal clearance after
mounting. It is, however, important to verify the shaft
diameters (Tables 4, 5, and 6) and to measure the
unmounted internal clearance to ensure conformance to
specifications (Table 3).
2.
Install the bearing parts in the following sequence (refer to
parts drawing):
a.
V-ring Seal—Slide one of the V-ring seals onto the shaft,
making sure lip is toward the bearing.
Note: Do not install V-ring seal on seal ring until
housing cap has been set in place and tightened.
b.
Seal Ring—Install a seal ring on shaft with largest O.D.
toward bearing.
c.
Bearing—Install bearing. Bearings with cylindrical bore
up to 70 mm may be cold mounted on the shaft. Apply
coat of light oil to the shaft and bearing bore, then press
on the bearing by mechanical or hydraulic device or use
the mounting nut to drive the bearing onto the shaft.
Bearings with cylindrical bore above 70 mm are heated
for mounting on shaft. Bearings, heated in oil between
93°C and 102°C, should have the bore wiped dry with
a clean cloth and while bearings are still in a heated
condition, they should be rapidly pushed on the shaft
and positioned squarely against the shoulder. A slight
twisting motion during fitting facilitates the mounting.
Large bearings are generally handled with a hoist or
crane.
The use of proper safety equipment including heat
resistent gloves is required for all steps.
Table 3 - Radial Clearance of 222 Series Spherical
Roller Bearings (Straight Bore)
Basic Bearing No.
22209
22210
22211
22212
22213
22214
22215
22216
22217
22218
22219
22220
22222
22224
22226
22228
22230
22232
3
C3 Radial Clearance (mm)
Min.
Max.
.055
.075
.055
.075
.065
.090
.065
.090
.065
.090
.080
.110
.080
.110
.080
.110
.100
.135
.100
.135
.100
.135
.100
.135
.120
.160
.120
.160
.145
.190
.145
.190
.170
.220
.170
.220
MN3066