A-120
VCF 1
0 db
Fig. 2:
How resonance affects the response of a low
pass filter
4. In / Outputs
! CV 1
Socket CV 1 is the filter's standard voltage control
input, and works on the 1V / octave rule, like the
VCOs.
If you patch a modulation source (eg LFO, ADSR) to
this input, the cut-off frequency of the filter will be
4
System A - 100
modulated by its voltage: ie., the sound color changes
according to the voltage put out by the modulator.
If you use the VCF as a sine wave oscillator, connect
Resonance
the pitch CV into this socket. Do the same if you want
the filter's cut-off frequency to track exactly with the
pitch of a note.
" CV 2
Sockets CV 2 and CV 3 are also voltage control
inputs for the filter. Unlike CV 1, you can control the
level of voltage - the intensity of modulation effect on
the filter - with attenuators 2 and 3.
Frequency ➨ ➨ ➨ ➨
f c
$ Audio In
This is the filter's audio input socket. Patch in the
output from any sound source (eg. VCO, noise gene-
rator, mixer).

% Audio Out

Filter output % sends out the filtered signal.
§ CV 3
doepfer