Doheny's 2459 Series Instalasi - Halaman 2

Jelajahi secara online atau unduh pdf Instalasi untuk Filter Kolam Renang Doheny's 2459 Series. Doheny's 2459 Series 3 halaman. Automatic chlorine feeders

Doheny's 2459 Series Instalasi
6 Drill a 3/8 in. hole at location identified in Step 2 of
Planning Installation section. Install Saddle Fitting
as in Step 5 above.
7. Connect inlet and outlet tubing to the Saddle Fittings
with Compression Nuts as in Step 3 above. Do not
over tighten.
Notice
: After starting up system, re-check all
Connections for leaks. Re-tighten as required.
II DIRECTIONS FOR USE
General
Before using your chlorine feeder, your pool/spa
water should be properly balanced and conditioned
and should have a chlorine residual of approximately
1.0 to 1.5 ppm. Follow chemical manufacturer's
directions and instructions. Check chlorine residual
daily and adjust the dial valve for more or less
chlorine. The chlorine demand for pools and spas
varies based on usage, temperature and sunlight.
Initially, you'll have to experiment to determine
the proper amount of chlorine and the correct valve
setting required for your pool and filter time cycle.
Follow chemical manufacturer's instructions for
proper chlorine level.
Refilling Chlorine feeder
DANGER
!
• You can use 3 in. or 1 in. diameter slow-dissolving
Trichloro-S Triazinetrione Chlorine Tablets.
• Never mix chemicals as it may cause fire and/or
an explosion.
• Never mix Trichloro-S-Triazinetrione Chlorine
Tablets with Calcium Hypochlorite, or with any
other form of concentrated chlorine or other
chemicals. Fire and/or explosion may result.
• Never add any other types of chlorine, pH
adjusters, shock treatments or algaecides through
the skimmer. If these products must be used, they
should be added directly into the pool water.
• Never isolate chlorine feeder with valve or other
Devices.
WARNING
!
• Read and follow all Safety Instructions prior to
operating or servicing this chlorine feeder.
• To reduce the risk of injury, do not permit children
to use this product.
• Wear eye and skin protection while maintaining or
servicing this unit.
• Do not inhale fumes from the chlorine feeder or
chemical container.
• Chlorine feeder may be under pressure. Use
Caution removing cover.
10411 80th Avenue Pleasant Prairie, WI 53158 | Orders and Customer Care: 1-800-574-7665 | Fax: 1-800-323-5932 | Doheny.com
1. Shut off all pumps and pump timers.
2. Turn chlorine feeder flow control valve to 'OFF'
3. Verify chlorine feeder return line to pool is
unrestricted.
4. Wait one minute to relieve system pressure before
attempting to remove cover.
5. Remove cover.
6. Refill chlorine feeder with 3 in. or 1 in. diameter slow-
dissolving Trichloro-S-Triazinetrione Chlorine Tablets.
7. Secure cover to chlorine feeder.
8. Turn flow control valve to desired setting. Restart pump.
III MAINTENANCE
A To Change O-Ring 2458
1. Read and follow instructions in Step 1 to 5 in Refilling
Chlorine feeder section.
2. Remove the O-Ring and replace with a Doheny's
replacement O-Ring part #24572.
3. Replace cover. If chlorine feeder needs to be refilled,
read and follow instructions in Steps 6 to 8 in Refilling
Chlorine feeder section.
A To Change O-Ring 2457 & 2459
1. Read and follow instructions in Step 1 to 5 in Refilling
Chlorine feeder section.
2. Replace O-Ring with a Doheny's replacement
O-Ring part # 24573. Reassemble being sure Slip
Washers are in place on stem of Cover (Inside).
3. Replace cover. If chlorine feeder needs to be refilled,
read and follow instructions in Steps 6 to 8 in
Refilling Chlorine feeder section.
B To Remove Flow Control Valve Handle
Set pointer to FULL. Insert screwdriver in slot
opposite
pointer,
counterclockwise. This allows the handle index lock
tab to clear the body ridge.
C Winterizing
Where freezing temperatures can be expected, drain
all water from chlorine feeder, (For in-line
permanently- installed unit, remove drain plug).
Carefully remove undissolved tablets and rinse out
chlorine feeder thoroughly with water. Replace cover
and drain plug.
D Vacuuming
When vacuuming, close flow control valve to prevent
bypass of sediment and possible clogging of control valve.
E Lubrication
Never use petroleum type lubricants on Cover
O-Ring. Use Magic Lube part #1185 to lubricate.
lift
up
and
rotate
handle