Safety Instructions
Make sure the switch is in the OFF position and tool is unplugged when changing a bit
Do not allow chemicals such as acetone, benzene, thinner, trichloroethylene ketone, or
other similar chemicals to come in contact with the screwdriver housing as damage
will result.
Do not drop or misuse the screwdriver.
Do not adjust the torque setting higher than 8 on the torque scale.
There should be a tool rest interval for cycles of three seconds or longer. This tool is
intended for a duty cycle of 0.8 seconds on, 3.2 seconds off.
Do not tighten more than 800 tapping screws (size: 3mm. Length: 5mm) per hour.
Do not use this screwdriver for tightening wood screws.
Do not operate the Forward/Reverse Switch while the motor is running.
Turn the switch to the OFF position and unplug the screwdriver and power supply
when the tool is not in use
Always grasp the plug of the power cord when plugging in/unplugging.
Always secure the power supply to avoid movement.
If the power supply overheats or is overloaded with maximum current rating, the
high-speed fuse will cut off the power. If this situation continues, stop operation
immediately and contact ASG for repair.
Do not disassemble the electric screwdriver or try to repair it yourself.
Description of Operation
Inserting/Removing Bit and Bit Type
Push up the holder clamp to unlock it. Thus, the bit can be freely attached and detached.
Insert the power plug into a receptacle and set the switch to "F" (forward position)
Apply the bit to the screw head and either press the lever or push to start the tool. The
switch will be turned ON to start the motor running.
When the screw is tightened and reaches the torque that you had set, the tool will
stop automatically.
To reverse the screw, set the changeover switch to "R" (reverse position).
Do not operate this tool without protective earth connected
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
44110-3898
| Phone: (
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com | Revision: 8/24/2020 | Page 2 of 3
888) 486-6163
216) 481-4519
Grounding Instructions
The tool should be grounded while in use to protect the operator from electric shock.
The tool is equipped with a three-conductor cord and three-prong grounding-type plug
to fit the proper grounding-type receptacle. The green (or green and yellow) conductor
in the cord is the grounding wire. Never connect the green (or green and yellow) wire
to a live terminal.
Green and Yellow
Blue
Brown
Installation Instructions
Use the power supply voltage recommended in the specification of this manual.
When using a commercial power supply be sure to set up circuit and safety
breakers. You must also properly ground the mechanisms.
The temperature and humidity should be kept at appropriate levels.
Do not set up the power supply in a room that has poor ventilation and where it
may be exposed to dust and metallic particles.
Do not put anything on top of power supply
Attach the power supply securely to a flat, stable surface.
Do not permit unauthorized personnel to operate this power supply or electric screwdriver.
Do not set up the power supply near any high voltage machinery
Avoid setting up or storing the power supply in wet or oily environments or where
it might be exposed to corrosive or flammable gases.
Earth
Neutral
Live