PROBLEM
*Power Team recommends these hand pump repairs be performed by an Authorized Hydraulic Service Center.
© SPX FLOW INC.
14
Original Operating Instructions Hand pump CFT 700bar, Hand pump CFT U
CAUSE
1. Air trapped in system.
-
1. This is normal operation on
most two-stage hand
pumps.
12
SOLUTION
1. Position cylinder lower
than pump. Extend and
return cylinder several
times. Follow bleeding
instructions.
instructions.