3M Aura 9312+ Lembar Data Teknis
Jelajahi secara online atau unduh pdf Lembar Data Teknis untuk Produk Pernapasan 3M Aura 9312+. 3M Aura 9312+ 4 halaman. Particulate respirators
3M
Personal Safety Division | 3M
™
3M
Aura
™
Respirators 9300+ Series
Technical Data Sheet
Description
The 3M
Aura
Particulate Respirator 9300+ Series provides
™
™
effective respiratory protection for use in environments
where workers will be exposed to airborne dust particles and
non-volatile liquid particles.
•
Tested and compliant with AS/NZS 1716.
•
Can provide protection against mechanically (P1) and
thermally generated particulates (P2).
•
Foldable, easy to store, 3-panel design accommodates
facial movement for wearer comfort.
•
Sculptured nose panel conforms to the nose and contours
of the face and helps improve compatibility with 3M
eyewear.
•
Embedded nose clip is concealed and is metal detectable.
•
Nose clip is kept securely in place within the layers of the
respirator.
•
Large, soft nose foam comfortable on the skin
•
Hygienic individual packaging helps protect the respirator
from contamination before use
•
3M low breathing resistance filter technology
gives effective filtration for consistent high quality
performance.
•
Embossed top panel of the respirator helps to reduce
fogging of eyewear.
•
Innovative chin tab designed for ease of donning and
adjustment to help achieve a more comfortable fit.
•
3M
Cool Flow
exhalation valve offers improved
™
™
comfort in hot humid environments and/or where work is
hard and physical (9312+, 9322+).
•
Even strap pressure improves comfort on the neck, face
and head with a secure feel.
•
Coloured headbands for easy identification: Yellow for P1,
Blue for P2.
™
Particulate
™
Particulate Respirators 8825+ and 8835+
Standards
The 3M
Aura
Particulate Respirator 9300+ Series
™
™
respirators meet the Class P1 or P2 performance requirements
of AS/NZS 1716:2012 for filtering mechanically (P1) and
thermally (P2) generated particles. They should be used to
protect the wearer from solid and non-volatile liquid particles
only. Class P2 respirators are also recommended for use
in certain applications against some pathogenic biological
airborne particulates such as Influenza virus. A copy of
AS/NZS 1716:2012 can be purchased from SAI Global.
Applications
These respirators are suitable for use in concentrations of
solid and non-volatile liquid particles up to the following
limits:
AS/NZS 1716
Model
Classification
9310+
P1
9312+
P1
9320+
P2
9322+
P2
ES = Exposure Standard
Note: Respiratory protection is only effective if it is
correctly selected, fitted and worn throughout the time
when the wearer is exposed to hazards.
Exhalation
Protection
Valve
Factor x ES
Unvalved
Up to 10x
Valved
Up to 10x
Unvalved
Up to 10x
Valved
Up to 10x