Do not work on pump until power is unplugged.
Do not cut off ground pin or use an adapter
fitting.
Do not use an extension cord.
The pump power cord should be connected to a
separately fused, grounded line with a minimum
capacity of 15 amps.
1. Before installing or servicing this pump, be
certain pump source is disconnected.
2. Installation and electrical wiring must adhere
to state and local codes and must be
completed before priming pump. Check
appropriate community agencies, or contact
local electrical and pump professionals.
3. Call an electrician when in doubt. Pump
should be connected to a separate 15
amp circuit breaker or 15 amp fuse block.
Note that plugging into existing outlets may
cause low voltage at motor. This could cause
blown fuses, tripping of motor overload or
burned out motor.
4. For maximum safety, connect pump to a circuit
equipped with a fault interrupter device when
positioning the pump's grounding wire.
5. Voltage of power supply must match the
voltage of the pump.
6. Before installing pump, clear of any water,
debris or sediment.
7. The following may cause severe damage to
pump and will void the warranty.
(a) Using an extension cord.
(b) Cutting off the ground pin or using an
adapter fitting.
(c) Working on pump or switch while
plugged in.
(d) Removing motor housing, unscrewing
impeller, or otherwise removing impeller
seal.
(e) Running the pump continuously.
Utility Pumps
Model: UT57
Installation
(f) Pumping chemicals or corrosive liquids,
(g) Pumping gasoline or other flammable
(h) All piping must be clean and free of all
(i) Pump will be inadequate if suspension
ELECTRICAL WIRE CONNECTION
shown on the nameplate corresponds to those
available on the mains. The installer must make
sure that the electric system is grounded in ac-
cordance with code.
• For outdoor use it is necessary to use cable
with a length of at least 8'. The plug and
connection should be protected from water
splashes. Before using the pump, always in
spect it visually (especially power cable and
plug)
• Do not use pump if it is damaged
• If the pump is damaged, have it inspected by
an authorized service center.
• Make sure that electric connections are pro
tected from flooding. Protect the plug and the
power cable from heat or shape edges.
nel only. Grounding: The plug of the power cable
has a double grounding contact, so that ground-
ing can be performed by simply inserting the
plug.
OVERLOAD PROTECTION
This pump series has a built in thermal protection
switch. The pump stops if an overload condition
occurs. The motor restarts automatically after it
has cooled down.
5
other than motor oil.
liquids
foreign matter to prevent clogging.
liquids contain solid particles larger
than 1/4"
Verify that the voltage and
frequency of the pump
The power cable must be re
placed by qualified person-