Acquisitions HIW-XF03G Instalasi & Petunjuk Pengguna - Halaman 6

Jelajahi secara online atau unduh pdf Instalasi & Petunjuk Pengguna untuk Perapian Dalam Ruangan Acquisitions HIW-XF03G. Acquisitions HIW-XF03G 16 halaman.

4.1

VENTILATION

A minimum of 100 cm 2 purpose provided ventilation is required for this appliance. This may be achieved
either with one vent 100 cm 2 at a high or low position in the room, or split ventilation i.e. 50cm 2 be
installed at high level and 50cm 2 be installed at low level within the room.
An openable window or equivalent is also required. The requirements of other flued appliance operat-
ing in the same room or space must be taken into consideration when assessing ventilation.
Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2. Ventilation fitted under,
or within immediate vicinity (500mm) of the appliance must not be used as it may adversely effect per-
formance of the ODS system.
The appliance MUST NOT be installed in a bedroom, bathroom or any sleeping area. For Republic of
Ireland, see relevant rules in force.
5.0

UNPACKING THE APPLIANCE

Remove the straps and the top lid of the outer packaging, remove any instructions or fixing kits.
Read ALL these instructions before continuing to unpack or install this appliance.
Lift off the remaining packaging components.
Check that the components supplied correlate with the component checklist. Please dispose of all the
packaging materials at your local recycling centre.

COMPONENT CHECKLIST

5.1
QUANTITY
1
1
1
1
1
6.0

GAS SUPPLY ROUTES

There are three possible entry points for the gas supply pipework to enter the appliance firebox. These
entry points are 'knock out' type holes.
Non-concealed gas connections may be made using the entry points at either end of the firebox or the
one in the bottom of the firebox. A concealed gas connection may be made using the knock out hole in
the centre back of the firebox. Select the most appropriate entry point and knock out the relevant holes
in both the firebox and the outer casing.
No more than 1.5m of 8mm diameter pipe must be used to avoid unnecessary pressure drops.
If a concealed gas connection is to be made, the supply pipe should always be sleeved through walls
and floors using the shortest possible route.
For concealed supply pipe routing, pipes must (where possible) be vertical and providing there is suffi-
cient wall thickness available, they should be placed in pipe chases. Horizontal pipe runs should be
avoided. Prior to chasing a solid wall, an inspection should be made to note the proximity of any
cables/sockets outlets which may already be buried. Pipes must be secured using suitable clips and pro-
tected against corrosion. Ideally factory finished protected pipework and fittings should be used. Joints
should be kept to a minimum and compression fittings must not be used. The pipework installation must
be tested for soundness before any protection is applied and/or the pipework and fittings are buried.
If the appliance is to be mounted on the inner leaf of a conventional cavity wall, or a solid wall, drill the
required number of holes using a 7mm masonry bit. Insert the
fibre wallplugs as required.
If the appliance is to be mounted on a dry lined wall or a tim-
ber framed construction wall then special cavity screw fixings
will be required which are not supplied with this product. These
should be constructed from metal and not plastic.
If a concealed gas connection is to be made ensure the gas sup-
ply pipe is in it's final position and can enter the appliance in
the correct position when the appliance is hung on the wall.
DESCRIPTION
Firebox and burner assembly
Set of manufacturers instructions
Decorative frame assembly
Screw and wall plug pack
Rubber grommet
4