4
The RSL-6A and RL-1A are available for the American market. They have identical
operation to the RSL-6 and RL-1 but have been designed to fit a single gang US electrical
outlet box. Front panel dimensions are 4 1/2"×2 3/4"
8
Music Equalisation
Separate treble and bass controls are provided for music signals on each zone. This
arrangement allows the installer to optimise the response of the music signals on a zone by
zone basis where different acoustic properties require optimal equalisation adjustment. The
equalisation controls are on the rear panel. The music treble control (HF) has a range of
±10dB at 10kHz and the music bass control operates with a range of ±10dB at 50Hz.
9
Priority
The Cloud 36/50 has a facility to allow fully automatic priority to a JukeBox or Spot
Announce Player on both zones. Internal priority jumpers J12 (Zone1) and J13 (Zone2) can
be repositioned to the 'ON' position to enable this in either or both zones. Jumpers J12 and
J13 can both be found located approximately 150mm behind the Zone 2 microphone level
control
When this priority mode of operation is selected, the zone will operate normally until a signal
is detected on Line Input 6; this will cause the selected signal (usually background music) to
mute, allowing the signal on Line 6 to operate with priority. Once the signal on Line 6 ceases,
the selected music signal will smoothly restore to its former level; the time taken for this
restoration can be set at 3, 6 or 12 seconds by fitting the appropriate jumper (J11) on the
main printed circuit board. The factory default restoration time is 3 seconds.
When setting the jumper(s) please ensure that you:
• Remove the mains cable from the rear of the product before removing the top panel.
• Only reassemble the unit using bolts/screws identical to the original parts.
06/12/02 V5.0
Location of Jumpers J12 and J13
Location of Jumper J11
36/50: Installation and Operation Manual