Acquisitions X-FIRE Widescreen Instalasi & Petunjuk Pengguna - Halaman 15
Jelajahi secara online atau unduh pdf Instalasi & Petunjuk Pengguna untuk Perapian Dalam Ruangan Acquisitions X-FIRE Widescreen. Acquisitions X-FIRE Widescreen 16 halaman.
3.0
VENTILATION AND ROOM SIZE (continued)
A supply of fresh air into the room is advisable to maintain temperatures within limits.
The appliance MUST NOT be installed in a bedroom or bathroom.
For Republic of Ireland, see relevant rules in force.
X-Fire 1000 models : The room size should be a minimum of 30m 3 (e.g. 11'6" x 11'6" x 8') to
allow adequate circulation of air and ensure the correct operation of the fire.
X-Fire Widescreen models : The room size should be a minimum of 40m 3 (e.g. 13'4" x 13'4" x 8')
to allow adequate circulation of air and ensure the correct operation of the fire.
This volume may include adjacent spaces but these spaces must not be separated by a door. To cal-
culate a room size in cubic metres (m 3 ) divide the room volume in cubic feet (ft 3 ) by 35.3.
This appliance is intended as a secondary source of heat only and should not be used in a room with-
out some form of background heating present.
4.0
OPERATING INSTRUCTIONS
The pilot is visible behind the left hand side of the burner.
The control knob is located on the lower right hand side of the
outer case. It is of a spherical design and is marked as shown
in the diagram to the right;
Push in and turn the control knob to the SPARK position, and
hold there for a few seconds.
Continue turning anti-clockwise through the spark click to the
PILOT light position, ensuring the pilot has lit. If not, return the
knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed
for approximately ten seconds. Now release the knob and the
pilot should stay alight.
If the pilot is extinguished during use, wait three minutes
before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwise to
the high position. The main burner should light after a few seconds.
To decrease the setting to LOW, turn the control knob clockwise to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to
the pilot position and release.
To turn the fire OFF, keep the knob pressed in, return to the off position and release.
COMBUSTION MONITORING SYSTEM
5.0
This fire is fitted with a combustion monitoring safety device (ODS). If the appliance shuts down dur-
ing use for no apparent reason then several reasons may be suspected. If a door or window has been
opened creating a draught, then pilot disturbance could be the problem and removal of the draught
should resolve this. The appliance can then be re-lit in accordance with the previous section.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appli-
ance OFF, call in your installer to check the appliance and ventilation. Remedial work must be carried
out as required. DO NOT allow the appliance to be used until the appliance and installation is passed
as safe. If the pilot continues to be extinguished, you must call your installer to check the operation of
the complete appliance.
3
'OFF' position
'SPARK' position
'LOW' position
'HIGH' position