Wiring the rackmount
housings
Inputs:
The transformer inputs should be connected to the low-
impedance output of the relevant amplifier channel. Use
the mating 2-pin 5 mm-pitch screw-terminal connectors
supplied with the transformers, and wire with two-core
stranded cable of at least 1.5 mm
model CXL-400T, 2.5 mm
cable is recommended if the
2
transformers are not adjacent to the amplifier.)
Outputs:
The transformer outputs may be connected to the
loudspeaker system. Use the mating 3-pin 5 mm-pitch
screw-terminal connectors supplied with the transformers,
and two-core stranded cable of at least 0.75 mm
(CXL-40T, CXL-100T & CXL-200T) or 1 mm
(CXL-400T). Note that pins 1 and 3 should be wired for a
100 V-line system, and pins 1 and 2 for a 70 V-line system.





When all the connections have been made, fit the PVC
external safety cover over the rear panel connectors. The six
fixing holes in the cover should align with the six hex pillars.
Secure it in place with six of the supplied M3 x 6 mm Pozi
screws.