Acquisitions BLOOMSBURY SE 8kW Instalasi & Petunjuk Pengguna - Halaman 14

Jelajahi secara online atau unduh pdf Instalasi & Petunjuk Pengguna untuk Kompor Acquisitions BLOOMSBURY SE 8kW. Acquisitions BLOOMSBURY SE 8kW 16 halaman.

in your area. Petro coke should not be used as it burns very hot and may damage the
stove casting.
The above text should be used as a guide only. The ideal operation of
your stove depends on a number of factors, which vary with each
installation, and so gaining experience operating your stove is the only
way to learn its best operation.
The stove as with any other metal products will expand and contract. A
ticking noise may occur. This is normal for this type of appliance.

TECHNICAL INFORMATION

Normal heat output - wood
Nominal heat output - solid mineral fuel
Weight of stove
Minimum chimney draught
Mean flue gas temperature - Wood
Mean flue gas temperature – solid mineral fuel
Flue gas mass flow – Wood
Flue gas mass flow – solid mineral fuel
7.6kW
7.1kW
99kg
12Pa
229°C
215°C
6.4g/s
7.3g/s
Page 14
AB-8kW-I03-191213