Ashly PE-2400 Panduan Pengoperasian - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Penguat Ashly PE-2400. Ashly PE-2400 13 halaman. Pe series high performance professional power amplifiers
Juga untuk Ashly PE-2400: Catatan Teknis & Spesifikasi (2 halaman), Instalasi dan Panduan Pengguna (2 halaman), Lembar Spesifikasi (2 halaman), Panduan Pengoperasian (13 halaman)
Page - 6
Important Safety
Instructions – 2
Introduction - 3
The PE Series - 4
Physical Description - 5
Front Panel
Rear Panel
Input Module
Installation – 6
Requirements
Typical Applications
Connectors & Polarity
Operation - 8
Troubleshooting - 9
Spec Table - 10
Measurements - 11
Dimensions - 12
Warranty - 13
PE-Series amplifiers are designed for use in both fixed and mobile sound systems. Each
amplifier is shipped (unless otherwise specified) with the following factory settings:
Front panel:
On/Off Switch = Off
Attenuators =
Before connecting to mains power, make sure that the switches are set to the configuration
needed for your particular application. Always switch the amplifier off before making any
changes to the settings. Failure to do so could result in damage to the unit or other components
in your system. CAUTION: When mounting or connecting the amplifier, always disconnect it
from the mains. Use four screws and washers when mounting the amplifier to the front rack
rails. Rear support is also recommended, especially for mobile or touring use. To reduce the
risk of fire or electric shock, do not expose this apparatus to rain or moisture.
Input Module
The PE-Series has been designed
with flexibility in mind. The input
section illustrated at right has been
engineered in modular form. All
amplifiers ship with the standard
input (shown) unless the Optional
NE
32 bit/96kHz Protea
DSP card is
specified. This optional module
features both analog and digital
(AES/EBU) inputs, and two
additional processed output channels to drive additional amplifier channels.
Documentation for this module is provided in a separate document. If there is an input
feature or function you'd like to see developed for the PE-Series, please contact Ashly.
1.
XLR/TRS Combo Balanced Inputs – These
connectors accept either a Male XLR or 1/4"
TRS connector
2.
Channel Input Turnarounds – These
connectors provide signal to additional
amplifiers via male XLR connectors.
3.
Euroblock Connector Channel Inputs –
These connectors are in parallel with the
Combo Inputs and allow for signal connection
using Euroblocks.
4.
Remote Level Control Connector – This
connector facilitates hard-wired remote
attenuation control.*
Requirements
PE-series amplifiers have specific physical, electrical and signal requirements for proper
operation. These requirements will vary depending on your specific application, setup, and
the settings on the amplifier. When setting up and testing your system, please take special
care to double check all connections and settings. Please refer to the specifications section
of this manual for specific input, output and other figures.
Copyright© 2007 – Ashly Audio Inc.
Operator Manual – PE Series Amplifiers
5.
Remote Standby Connector – This connector
facilitates hard-wired remote on/off
functionality.*
6.
Ethernet Connector & Indicators – This CAT-
5 Ethernet connector interfaces with a Protea
NE network, or computer if available. The
indicators show network link and data activity.
*See the wiring diagram on page 12 for more
information.
Rear panel:
Input Ground Lift = Grounded
High Pass Filters (both Ch.) = Off
Mode Selector = Stereo
Clip Limiter = Off
Gain Selector = 32 dB