SPX-XXXX Application Note
Using Supervised Contacts with the SPX-series Extenders
Applies to the following products: SPX-5501, SPX-5601, SPX-5521, SPX-5621, SPX-7400,
SPX-7410, SPX-7200, SPX-7500, All RIM series products.
This application note describes the connections necessary to convey supervised contact status over
a Suprex® communication link. The configurations described in this app note should apply to most
panels that utilize supervised contacts. When connected as described, the Suprex® system will
provide a supervised signal to the panel interface by reading the supervised status of the contacts
connected to the Suprex® Remote unit.
Theory of operation: The Access control panel is looking for a certain value of resistance
connected to the supervised contact terminals. The Suprex® Central unit will provide these
resistance values locally at the panel so that the correct supervised status is maintained. At the
same time, the Remote unit must maintain supervision of the wires connected to the relays and
switches that are connected to the remote access point. The contact supervision is provided by the
Remote unit. The Suprex® system does this by comparing the value of programming resistor at the
Central unit with the resistance seen at the Remote interface terminals. When there is a difference
in the two values, the Relay on the Central unit is activated.
There are two different examples. One example is monitoring a normally closed contact at the
Remote unit, and the other example is monitoring a normally open contact at the Remote unit. In
the examples given, a normally closed contact will require a programming resistor of 1K and a
normally open contact will require a programming resistor of 2K. Other resistor values can be used
but 1K resistors are the most common. Other resistance values will require different value(s) for the
programming resistor(s).
1K
2K
Door
N.C.
Contact
Rex
N.O.
Contact
8 to 16 VDC In
Ground
Diagnostic LED
exp (+)
exp (-)
Central Unit
+5 VDC out
Prog Res 4
Prog Res 3
LED In
D1/Data out
D0/Clk out
1K
1K
1K
1K
Relay 4 N.O.
Relay 4 Com
Relay 4 N.C.
Relay 3 N.O.
Relay 3 Com
Relay 3 N.C.
Ground
Aux out
R2 in
R1 in
8 to 16 VDC In
Ground
Diagnostic LED
exp (+)
exp (-)
Remote Unit
+5 VDC out
R4
R3
LED out
D1/Data In
D0/Clk In
I1-
1K
I1+
I2-
1K
I2+
Relay 2 N.O.
Relay 2 Com
Relay 2 N.C.
Relay 1 N.O.
Relay 1 Com
Relay 1 N.C.
Ground
Aux in
Not used
Not used