AMBIC EasiDoser Panduan Petunjuk Pengoperasian - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Peralatan Pertanian AMBIC EasiDoser. AMBIC EasiDoser 16 halaman.
Ambic Equipment Ltd – EasiDoser™ Operating Notes
Installation (refer to Fig.1, 2, 4)
Electrical Installation - should ideally be carried out by a Qualified Electrician – The 3-core power supply
cord MUST remain accessible when the unit has been installed and MUST be connected to Earth. THIS
ELECTRICAL SUPPLY SHOULD BE PROTECTED BY AN APPROPRIATE EARTH LEAKAGE CIRCUIT
BREAKER.
CAUTION: To avoid severe or fatal shock, always disconnect main power when
servicing the unit.
Chemical – is sucked up from a chemical container by peristaltic pump(s).
The enclosure housing the
EasiDoser™ pump(s) is rated at IP44 (IEC 60529); the power unit (A) must, therefore, be positioned in a
dry location and close to a 220-240V AC power socket (Maximum Power consumed: 50W).
The enclosure (A1) should be positioned no more than 2 metres vertically above the floor and no more
than 3 metres distant from the chemical container(s). Use the drilling template to mark out screw positions
and fix the enclosure to a suitable flat surface, using the screws and plastic plugs supplied.
The chemical container(s) (D) should be placed securely on the floor and the inlet tube(s) (C) from the
pump enclosure should be connected to the inlet nipple(s) of the peristaltic pump(s) – each PVC inlet tube
should be measured for correct length (cutting the excess tube) and warmed before being pushed over the
peristaltic pump spigot and secured with the stainless steel hose clips. Make sure that clips are fitted so
that the barb of the fitting on the pump is central in the clip and do NOT over tighten the clip (you risk
Drop the filter end of the inlet tube(s) into the chemical container(s) –
breaking the plastic nipple).
ALWAYS ENSURE that each inlet tube has a FILTER FITTED.
CAUTION: Wear protective clothing and eyewear when dispensing chemicals or any
other materials. Observe safety handling instructions (MSDS) of chemical manufacturers.
Layout
Fig. 2 – General layout for a Single EasiDoser
™
™
Fig. 1 - General Layout for Twin EasiDoser
-4-
ADE7500 v1.3 (16/03/18)